GAOTek 2m digital transmission analyzer for channel and signaling testing is a multi-functional and full- featured digital transmission system test device, designed for installation testing, engineering checks and acceptance, and daily maintenance of digital networks, mainly performing channel testing, alarm analysis, fault finding, and signalling analysis. In addition, this instrument further provides various protocol converters with one-way and bi-directional bit error test functions. These capabilities make it ideal for field use.
Technical Specifications
TX – Transmitter
| Output Interface | 75 Ohm balanced, conforming to G.703 requirements |
| Signal Structure | Unframed; Frame (PCM30, PCM31, PCM30CRC, PCM31CRC), conforming to G.704 n×64 Kbit/s structure |
| Line Code | HDB3 or AMI |
| Signal Rate | 2048 kbit/s |
| Internal Clock Accuracy | ≤ ±10 ppm |
| Clocking | Internal, external, and distilled |
| Output Intrinsic Jitter | < 0.05 UI (20 Hz to 100 kHz) |
| Test Pattern | Pseudo-random sequence 2E6 to 1, 2E9 to 1, 2E11 to 1, 2E15 to 1, 2E20 to 1, 2E23 to 1, conforming to ITU-T O.151; Manchester code, 8-bit |
| Free TS Pattern | 8-bit Manchester mode |
| Code Error Insertion | FAS ERR: Once, continuous twice, continuous 3 times, continuous 4 times BIT ERR: Single, 1E-2 to 1E-7 |
| Pattern Slip | PAT slip |
RX – Receiver
| Signal Input Impedance | Terminal: 75 Ohm unbalanced, Tx loss conforms to G.703Bridge: >750 Ohm unbalanced Monitor: 20 dB input sensitivity |
| Signal Input Equalizing Feature | 0 to 9 dB |
| Signal Input Jitter Capacity | Conforms to G.823 |
| Input Anti-Interference | Conforms to G.703 |
| Signal Structure | Unframed; Frame (PCM30, PCM31, PCM30CRC, PCM31CRC), frame signal conforms to G.704 n×64 kbit/s structure |
| Line Code | HDB3 or AMI |
| Signal Rate | 2048 kbit ±50 ppm |
| Test Pattern | Pseudo-random sequence 2E6 to 1, 2E9 to 1, 2E11 to 1, 2E15 to 1, 2E20 to 1, 2E23 to 1, conforming to ITU-T O.151; Manchester code, 8-bit |
| Frequency Test | For line signal and voice channel signal |
| Level Test | For line signal and voice channel signal |
| Bit Error Monitoring | FAS ERR, BIT ERR, CRC-4 code error performance test, CODE ERR |
| Alarm Monitoring | AIS, SIG LOSS, RA, MAR, FAS LOSS, CRC LOSS, PAT LOSS, PAT SLIP |
| Slip Monitoring | PAT SLIP, CLK SLIP |
| Time Delay Test | Tests time-delay performance |
| Bit Error Analysis | G.821, G.826, M.2100 |
| External Clock Input Impedance | Terminal: 75 Ohm unbalanced, Tx loss conforming to G.703Bridge: >750 Ohm unbalanced |
| External Clock Input Signal | HDB3/AMI conforming to G.703; pulse signal, >2.5 Vp-p |