Advanced Gas Chromatograph with Multi-Detector Configuration – GAOTek

High-precision gas chromatograph with 8-zone temperature control and FID, TCD, ECD, FPD, NPD detectors for fast, accurate analytical performance.

SKU: GAOTek-SPM-519 Category:
Description

Description

Technical Specifications

Main Parameters 

Parameters  Details 
Operation Display  8-inch high-definition color LCD touchscreen; can function as handheld controller 
Temperature Control Zones  8 zones 
Temperature Control Range  4 to 450 above room temperature; increment 1; accuracy ±0.1 
Program Temperature Stages  16 ramp stages (expandable) 
Temperature Ramp Rate  0.1 to 60/min 
Gas Flow Control  Precision mechanical valve flow control 
External Events  8 channels 
Auxiliary Control Outputs  2 channels 
Sampler Types  Packed column injection, capillary injection, six-port valve gas injection, automatic sampler 
Number of Detectors  Up to 3 detectors 
Detector Options  FID, TCD, ECD, FPD, NPD 
Injection Initiation  Manual or automatic (optional) 
Communication Interface  Ethernet: IEEE 802.3.1.3.2 

 

Technical Parameters 

Detector Type  Parameter  Specification 
Hydrogen Flame Ionization Detector (FID)  Detection limit  ≤5×10-12 g/s (cetane/isooctane) 
Baseline noise  ≤0.05 PA 
Baseline drift  ≤0.2 PA / 30 min 
Linear range  ≥10⁶ 
Thermal Conductivity Detector (TCD)  Sensitivity  S ≥10000 mV•ml/mg (benzene/toluene) (with amplification 1, 2, 3, 4 times optional) 
Baseline noise  ≤20 μV 
Baseline drift  ≤30 μV / 30 min 
Linear range  ≥10⁴ 
Electron Capture Detector (ECD)  Detection limit  ≤1×10-13 g/ml (propyl BHC-isooctane solution) 
Baseline noise  ≤0.03 mV 
Baseline drift  ≤0.2 mV / 30 min 
Linear range  10³ 
Radioactive source  ⁶³Ni 
Flame Photometric Detector (FPD)  Detection limit  (S) ≤5×10-11 g/s; (P) ≤1×10-12 g/s (methyl parathion – anhydrous ethanol solution) 
Baseline noise  ≤3×10-13 A 
Baseline drift  ≤2×10-12 A / 30 min 
Linear range  ≥10² for sulfur, ≥10³ for phosphorus 
Nitrogen and Phosphorus Detector (NPD)  Detection limit  (N) ≤5×10-13 g/s; (P) ≤5×10-13 g/s (methyl parathion – anhydrous ethanol solution) 
Baseline noise  ≤5×10-13 A 
Baseline drift  ≤2×10-12 A / 30 min 
Linear range  N ≥10², P ≥10² 

 

Note: The product is customized to 7 or 9 components as per the requirements. 

7-component system: Hydrogen (H2), Carbon monoxide (CO), Carbon dioxide (CO2), Methane (CH4), Ethylene (C2H4), Ethane (C2H6), Acetylene (C2H2)

9-component system: Hydrogen (H2), Carbon monoxide (CO), Carbon dioxide (CO2), Methane (CH4), Ethylene (C2H4), Ethane (C2H6), Acetylene (C2H2), Oxygen (O2), Nitrogen (N2)