Overview

GAOTek IP Camera Tester is a 4.3 inch IPS touch screen camera tester tool designed for the maintenance and installation of IP cameras, analog cameras, TVI, CVI AHD, SDI cameras, as well as for the testing of 4K H.264 /4k H.265 camera by mainstream. The 960×540 resolution enables it to display network HD cameras and analog cameras in high resolution. This unit supports many ONVIF PTZ and analog PTZ controls. The combination of touch screen and key buttons make the IP camera tester very user-friendly.

This IP tester is a great tool for Ethernet network testing, PoE power voltage testing, PING, and IP address searching. Its portable, user-friendly design with various functions make it an essential tool for all installers or technicians.

Key Features

  • 4.3 inch IPS touch screen, 960×540 resolutions
  • H.265 & H .264 IP, 4K video display via mainstream
  •  8MP TVI test, 3840 x 2160P 15 fps, 4xzoom, video record & playback, coaxial PTZ control & call OSD menu *
  • 5MP AHD test, 2560x1944P12.5F/ 20fps, 4xzoom, video record & playback, coaxial PTZ & call OSD menu *
  • 8MP CVI test, 3840 x 2160P 12.5/15fps, 4xzoom, video record & playback, coaxial PTZ & call OSD menu *
  • HD SDI/EX-SDI camera test, support 1080P 50/60 FPS *
  • Rapid ONVIF, Auto log in and display image, create testing report
  • AXIS, Hikvision camera test, enter ONVIF app, input username and password to test
  • CVBS camera test and PTZ control
  • IPC TEST (Non-ONVIF test), HIK test tool (Hikvision camera), DH test tool (Dahua camera)
  • Video level meter, peak video signal level, SYNC signal level, Color bar chroma level measurement*
  • DC12 V/2 A power output, camera can be powered from DC 12 V
  • 48 V PoE power output power
  • Rapid video, just by one key to detect and auto display all network cameras
  • Built in Wi-Fi, display image from the wireless camera, create WIFI hotspot
  • CVBS loop test, the tester sends and receives color bar generator signal, to check BNC cable
  • Enhanced Color bar generator, PAL/NTSC multi-system color bar video generator

Cable test:

  • Improvement cable tester, UTP cable, telephone cable etc order and connectivity test, can save testing report, if special number, need customized
  • RJ45 cable TDR test, test cable pair status, length, attenuation, reflectivity, impedance, skew etc
  • Cable tracer, search BNC cable, network cable and telephone cable from the mess cables *

Other functions:

  • Network tool: Ping, IP scan, Port Flash, DHCP server, Trace Route
  • POE & power information, DC12V& PoE power and voltage output /input measurement
  • TesterPlay: Tester, android version mobile phone and PC display at the same time
  • Shortcut button, drop-down menu, can select Poe power, IP setting, CVBS, LAN info, HDMI IN etc
  • HDMI input, 720×480p/ 720×576p/ 1280×720p/ 1920×1080p/ 1024×768p/ 1280×1024p / 1280×900p / 1440×900p display, record and snapshot *
  • Traffic monitoring, display network port or WIFI connection real-time upload and download speeds and other network parameters
  • Self -update software, you can install apps with android version
  • Media player, 4K video files and MKV/MP4 media files play
  • Quick office, quick office app (support excel, word, ppt format) doc. editable
  • 8GB SD card including
  • Display its genuine resolution of the IP camera images
  • Audio in, support record and save the audio/LED lamp, calculators, music players and other application tools
  • 7.4 V /5000 mAh Lithium Ion Polymer Battery, after 5~6 hours charging, working time lasts 10 hoursAppli

Applications

  • CCTV system installation and maintenance
  • Network cabling project installation and maintenance
  • Dome camera, IP TVI CVI AHD SDI 4K H.265 camera testing
  • Video transmission channel testing
  • PTZ controller

Technical Specifications

LCD Display New 4.3 inch IPS touch screen cctv tester 960×540 resolution
 

 

 

 

 

 

 

 

 

 

 

 

 

 

Video Mode

 

CVBS

1 channel BNC input & 1 channel BNC looped output,
Analog video level meter, peak video signal level, SYNC signal level, Color bar chroma level measurement*
PTZ control, RS485 control, Baud 600-115200bps, compatible with more than 30 protocols such as PELCO-D/P, Samsung, Panasonic etc
CVBS loop test the tester send and receive color bar generator signal, check BNC cable
 IP camera test 4k/H.265/H.264 IP Discovery/Quick ONVIF/IPC test /RTSP play /Client APK
Rapid video Auto view the video, create testing report
Hik test tool activate Hikvision camera, modify the user name, password and IP parameters
Dahua test tool Dahua camera test, modify the user name, password and IP parameters
Zoom Image 4x zoom, to enlarge image, Screen snapshot, record, save, view and record and play back
IP& CVBS test IP& CVBS test at the same time, converter test from analog to digital with dual test window
 Coaxial HD test* 8MP TVI camera test,3840 x 2160P 15 FPS, UTC control/ call OSD menu *
8MP CVI camera test,3840 x 2160P 12.5/15 FPS, UTC control d call OSD menu *
5MP AHD test,2560x1944P 12.5F/20F, UTC control d call OSD menu *
HD SDI/EX-SDI camera test, support 1080P 50/60 FPS *
HDMI input * 1 channel HDMI input, support 1080P *
Zoom Image 4x zoom, to enlarge image, Screen snapshot, record, save, view and record and play back
Analog Video out Color bar generator Output one channel PAL/NTSC color bar video signal for testing monitor or video cable
Power output  PoE power output 48V PoE power output, max power 24W
DC12V power DC12V /2A power output
 

 

 

Cable test

TDR cable test * BNC cable, network cable, telephone cable, RVV cable and elevator cable, cat 5/6 cable’s length and short circuit. measurement range 1.2KM *
Cable tracer * search BNC cable, network cable and telephone cable from the mess cables *
UTP cable test Test UTP cable connection status and display on the screen. Read the number on the screen
RJ45 cable TDR test

 

Test cable pair status, length, attenuation, reflectivity, impedance, skew etc. measurement range 180M.
TesterPlay screen projection: tester, mobile phone and PC display at the same time (For android version mobile phone)
Network test Trace route, Link monitor, DHCP server, port flashing, Ping test
Wi-Fi Built in WIFI, speeds150M, display wireless camera image
Audio test 1 channel audio signal input, test whether sound normal, 1 channel audio signal, to connect headphone
Data monitor Captures and analyzes the command data from controlling device, also can send hexadecimal
PoE test Measurement POE switch or PSE power supply voltage and cable connection status
Drop-down menu You can select PoE power switch, IP setting, CVBS, LAN info, HDMI IN functions, etc in any interface
External power supply DC 12 V 2 A
Battery Built-in 7.4 V Lithium polymer battery, 5000 mAh
Rechargeable After charging 5~6 hours, normal working time 10 hours
Operation setting OSD menu, select your desired language: English, Chinese, Korean, Russian, Italian, French, Polish, Spanish, Japanese, etc.
Auto off 1 min-30 min
Working Temperature 14 °F ~ 122 °F (-10 ℃—+50 ℃)
Working Humidity 30 %-90 %
Dimension/Weight 8.46 in x 5 in x 2.09 in (215 mm x 127 mm x 53 mm) / 1.81 lbs (0.82 kg)

*Functions are customizable

Ordering Information

Below are customizable functions. For adding Digital multimeter and cable tracer function into the tester, NO MOQ is required. For adding other below mentioned functions, MOQ will be 50 pcs. Customization function “T” will not go with functions “A/D/H/S”.
M Digital Multimeter: DC and AC voltage measurement, Resistance measurement, Continuity test, Diode measurements, Capacitance measurement
O Optical power meter: Wavelength: 1625, 1550nm, 1490nm, 1310nm, 1300nm, 850nm; Measurement range: -70 ~ +10 dBm (for optical power testing and Fiber link loss relative measurement)
V Visual fault locator: 10mW visual fault locator with 650nm wavelength can emit red laser sources to test multi-mode and single mode fiber’s bending and breakage, test range 10KM.
T TDR cable test: BNC cable, network cable, telephone cable, RVV cable and elevator cable, cat 5/6 cable’s length and short circuit. measurement range 1.2KM
A AHD camera test: 5MP AHD test, 2560×1944 P 12.5F/20F, UTC control/ call OSD menu
H TVI camera test: 8MP TVI camera test, 3840 x 2160 P 15 FPS, UTC control/ call OSD menu
D CVI camera test: 8MP CVI camera test, 3840 x 2160 P 12.5/15 FPS, UTC control d call OSD menu
S HD SDI/EX-SDI camera test: support 1080P 50/60 FPS
L Video level meter: PEAK, SYNC signal level, color burst chroma level measurement
C Cable tracer: search BNC cable, network cable and telephone cable from the mess cable

Packaging List

No. Item Description Quantity
1 Tester 1
2 Adaptor DC 12 V 2 A 1
3 Network Cable Tester 1
4 Polymer lithium ion battery (7.4 V DC 5000 mAh) 1
5 BNC cable 1
6 RS485 cable 1
7 SC, ST connector (only for optical power meter) 1
8 Multi-meter test leads one pair of red and black (only for the Multi-meter models) 1
9 Output  power cable 1
10 Audio cable 1
11 TDR alligator clamp (only for TDR models) 1
12 Safety cord 1
13 Tool bag 1
14 User Manual 1
15 8GB SD card 1
16 DC Power cable 1

Additional Information

Operation

Installing the Battery

The tester has built-in lithium ion polymer rechargeable battery. Prior to the use of the instrument, the “battery cables” should be well connected inside the battery cabin.
Pressing the keycontinuously can power on or off the tester.
Notice: Please use the original adaptor and connected cable of the device!
When the battery icon is full or the charge indicator turns off automatically, indicate the battery charging is completed.
When the Charge Indicator  turns off, the battery is approximately 90% charged. The charging time can be extended for about 1 hour and the charging time within 12 hours will not damage the battery.
Press the key  several seconds to restore the default settings when the instrument works abnormally.
Multi-meter: the red and black multi-meter pen must insert the corresponding port.
Warnings: Instrument communication port access is not permitted if the circuit voltage is over 6 V, otherwise damage the tester.
Warnings: Do not insert multi-meter pen in the current terminal to measure voltage

Instrument connection
IP camera connection

Power an IP camera with an independent power supply, then connect the IP camera to the IPC tester’s LAN port, if the link indicator of the tester’s LAN port is green and the data indicator flickers, it means the IP camera and the IPC tester are communicating. If the two indicators don’t flicker, check if the IP camera is powered on or the network cable is not functioning properly.

Note:

  1. If the IP camera requires PoE power, then connect the IP camera to the IP tester’s LAN port. The tester will supply PoE Power for the IP camera. Click on the icon labeled PoE to turn the PoE Power off or on.
  2. If use the tester’s menu to turn off the tester’s PoE power supply, the PoE switch and the power sourcing equipment are allowed to connect to the tester’s PSE port, and the PoE power will be supplied to the IP camera by the tester’s LAN port. On this condition, the tester cannot receive data from IP camera, but the computer connected to the PoE switch can receive the data via the the tester.

Warning: Poe switch or PSE power sourcing equipment only can be connected to tester “PSE IN” port, otherwise will damage the tester.

Analog camera connection

  1. Connect the camera’s video output to the IP tester’s VIDEO IN. The image will display on the tester after pushing the PTZ icon
  2. CCTV IP Tester “VIDEO OUT” interface connect to the Video input of monitor and optical video transmitter and receiver, the image display on the tester and monitor
  3. Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface Note: positive and negative connection of the cable. Support RS232 PTZ controller, connect the RS232 cable to RS232 interface of the tester.

HD Coaxial camera connection

SDI, CVI, TVI, AHD camera are classified as HD coaxial cameras. Hereby the following instruction of how to connect SDI camera to the tester is also applied to CVI, TVI, and AHD camera.

  1. Connect the SDI camera’s video output to the IP tester’s “SDI IN” interface, the image will display on the tester. The tester only come with SDI input interface. There is no SDI output interface.
  2. Connect the SDI camera or the speed dome RS485 controller cable to the tester RS485 interface.
  3. Support RS232 PTZ controller; connect the RS232 cable to RS232 interface of the tester.

HDMI IN (Optional)

DVR or other device’s HDMI in port connect to tester’s HDMI in port, the meter will display input image.

OSD menu

  • Press the key 2 seconds to turn on
  • Press the key  2 seconds to turn off
  • Short press the key  to enter sleep mode, press it again to test if tester work abnormally and cannot be turned off , Press the key several seconds to turn off, the tester reset

Click SD card, install or remove SD card.

Drop-down Menu

Press and slide at right top right corner twice to open shortcut menu. The shortcut menu includes POE power output, IP settings, Wi-Fi, HDMI IN, CVBS, Video OUT, LAN, Brightness, settings etc.

HDMI: Click HDMI IN to enter,In HDMI IN mode, it can converter test from analog to digital with dual test window IP & HDMIN or Analog & HDMI in.
CVBS: Click icon “CVBS “to enter, you can test IP and analog camera at the same time.
TV OUT: Click Video OUT to enter floating window, connecting the BNC cable to tester and appears analog video monitor interface, it can test circuit and BNC cable whether normal.
LAN: Display network port or WIFI connection real-time upload and download speeds and other network parameters.
Brightness: Set brightness.
Settings: Enter settings interface.
IP: Enter IP Settings interface.
POE power output: Turn on or off the tester “PoE power “app.
WLAN: Turn on WLAN net and displays current WLAN status.

Short cut-menu

  • You can call shortcut menu by pressing tester’s “menu” key and you can self- define shortcut -menu
  • Press the key , you can turn on it and switch functions, then press  to enter app, tap other area on the screen, to exit the menu
  • Short cut-menu setting, Long press any app in the all applications list, it will auto move to shortcut menu. If you delete any app in the short cut – menu, please select the app and press several seconds, it will be deleted.

Tester Play

Mobile screen projection (Only for android version)

The meter creates WIFI hotspot, connect mobile phone to the tester’s WIFI hotspot, or the tester and mobile phone connect to the same Wi-Fi network. Tap icon , then select “Tester Play” app to enter, click “Start” button to generates two-dimensional code, Please use mobile phone scan it, then download and install the client software, you can view the screen real-time projection.

Rapid ONVIF test

Rapid ONVIF can display 4K H.265/H.264 camera image by tester mainstream, one key to activate Hikvison camera.Press enter  ONVIF function, the meter auto scan all ONVIF cameras in different network segments. It lists cameras name and IP address on the Left of screen. Tester can auto login camera and display camera image. Factory default use admin password to auto login, if you modified the password, then default use the modified password to login

If you select ONVIF Rapid mode, the meter automatically scan different network segments for ONVIF cameras. It lists the camera name and IP address on the Device List. Tester can auto login camera and display camera image.
Click the button “Refresh”, tester will scan the ONVIF camera again. Click the newly displayed ONVIF camera on the “Device List“. The tester will show the IP camera’s relative information and settings.
Activate HIKVISION Camera: When connected inactivated HIKVISION Camera, tester can auto recognized, and prompt “The camera is not active, you need to activate it”, click “OK” to start activate.
Enter a new password for the camera

When it displays “activate success” prompt, click login to display camera image.
Pop-up settings menu: click the “ONVIF setting” icon in the upper left corner. The “ONVIF setting” window display.
Across network segments scan: After open this function , enter “Setting”-“IP Settings”-“Advanced” to add other network segments IP, Rapid ONVIF function can across network segments to scan camera’s IP.
Auto Login: After open this function, tester can auto login camera and display camera image (The login password is the same as last login, When logging in first time, password is the default password “admin”)
Video transmission protocol: UTP and TCP protocol
Open password cracker: Cracks password of cameras
View manual: Open Manual
Restore Defaults: Revert “Rapid ONVIF” to default settings
Confirm: Save the modified parameters
Click “MENU” icon to open camera setting.
While in the “Live video” menu, click “Video Menu” at the top right of the image to access the following tools: Snapshot, Record, Photo, Playback, PTZ and Settings
ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move. Tap the left side of the image to move left, right to go right, up to go up and down to go down. Compatible IP PTZ cameras will rotate accordingly. PTZ rotation direction is displayed on top left corner of the image.

PTZ
Set preset position: Move the camera to preset position, enter the preset number on the Bottom right corner to complete position preset.
Call the preset position: Select the preset number on the left, click “Call” to call preset

PTZ Speed set: Horizontal and Vertical Speed set
RTSP: Get RTSP address of the current camera
Doc: Auto generate test reports document of camera, click “Create document”. Click Preview to view the report document
Enter the camera test information, click “Create Document” to complete the report..

IP camera test

Display image from the 4K H.265 camera by mainstream
Click icon  to enter IP camera test

IPC test interface

Local IP: This is the tester’s IP address. Click “Edit” to enter “IP setting” and change the tester‘s IP address settings
IP camera type: Click on the IP Camera type to select the Manufacturer and model number of the integrated IP camera
Manual: Click IP camera type, list Honeywell, Kodak, Tiandy, Aipu-waton, ACTi, WoshiDA IP camera etc. If the brand has offered official original protocols, select camera type, input IP camera address, user name and password, click “official” to enter the camera image display interface
Stream code: When test camera via RTSP, you can select mainstream or sub stream to test (if camera’s RTSP have not been start or without, it will tip “auto match fail, please witch to manually selecting.

IP Camera’s IP: Enter the IP camera’s IP address manually or click “Search” to auto-scan for the IP camera’s IP address. It is better to directly connect the IP camera to the tester so the search results will only display the camera’s IP address. If the tester is connected to a PoE switch, it will find and display several IP address
IPC User Name: Enter IP camera’s user name
IPC Password: Enter IP camera’s login password
IPC Port :: When you select the IP camera type, it will default the camera’s port number and doesn’t need to be changed.
After all settings are completed, click “Enter” to view the live video

If IP address setting has error or IP camera is not connected. The tester prompts “Network Error”
Click  to quit from image display and return to IP camera test interface.

Video level meter

Click the icon to enter, the IP camera tester has adopted hardware high-speed sampling and processing technology, can perform both NTSC and PAL video amplitude signal measurements for PEAK to PEAK, SYNC levels and COLOR BURST Chroma level. When an analog signal is fed into the meter, the tester displays the measurements on the bottom left corner of the screen

NTSC Video signal level 140±15IRE
Chroma level( COLOR BURST) 40±5IRE
SYNC signal level 40±5IRE
PAL Video signal level 1000±200mV
Chroma level( COLOR BURST) 300±35mV
SYNC signal level 300±35mV

 

While in PAL format, the unit will be mV, While in NTSC format, it will be IRE.

IP camera video settings: Click “Video Set” to enter the IP camera’s encoder and resolution settings. Make the desired changes and click “OK “to save.

ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to move. Tap the left side of the image to move left, right to go right, up to go up and down to go down. Compatible IP PTZ cameras will rotate accordingly. PTZ rotation direction is displayed on top left corner of the image.

IP camera video settings: Click “Video Set” to enter the IP camera’s encoder and resolution settings. Make the desired changes and click “OK “to save.

Network tool

IP address scan

Connect the cable to the LAN port, click icon to enter, Set your IP address search range by changing the Start and End IP addresses. Click the “Start” button to scan the IP address range. You can also input an IP address in the Port Number Scan to scan for open ports.

PING Test

Connect a network cable to the LAN port and click the icon to open the PING tool. You can set your LOCAL (native) IP address, Remote IP address (e.g. IP camera), Packet count, Packet Size, Packet time and Timeout. Press “Start” to start pinging. If the IP camera or network device is not configured properly or not plugged in, it will say “Destination host unreachable,” or have 100% packet loss. If the tester connects to the device, the send and receive packets will have a 0% packet loss.

Application: PING testing is the most conventional network debugging tools. It is used for testing if the connected IP camera or other network equipment’s Ethernet port is working normally and the IP address is correct.It’s normal that the first data packet will be lost when test start.

 Network test (Ethernet bandwidth test)

To use the Network tester, you will need two IP testers. One is used as a Server and the other as a Client. Both devices must be on the same network segment in order to communicate. Click the icon to open the Network Tester app.

  1. Start the server: Click “Start Server” button to use the tester as a Server. It will display its IP address at the top of the screen.
  2. Start send packet test: Using the other IP tester, type in the Server’s IP address at the top right corner of the screen. This app is used to send packets for network speed testing. Click the “Start” button to send the packets and start testing.

Network bandwidth testing can also be tested with a computer using compatible network bandwidth testing software. Install network bandwidth testing software on a computer, as a test Client or Server, to do the mutual testing with the tester. If using the computer as the server, the computer IP address is: 192.168.0.39

Port Flashing

Connect a network cable to the meter’s “LAN” port, click the icon to open the Port Flashing app. Click “Start”. The IP tester sends a unique signal to make the connected LAN port of the switch flash.

If the tester and PoE switch are connected well, the LAN port of POE switch flash at special frequency, If not there is no changes on the LAN port.

Application:

The tester will send special signals to make the connected LAN port flicker at special frequency, which will enable the installers to easily and quickly find the connected Ethernet cable. This function can prevent mistakenly insertion or disconnection non-corresponding cable to artificially interrupt network connection.

DHCP server

Click on the DHCP icon to open the DHCP server app. Select the “Start” check box at the top and make any desired changes to the network settings. Click “Save” to start assigning dynamic IP addresses for IP cameras and other networked devices. Click the “Refresh” button to check your Client list.

Trace route

It is used to determine path of the IP packet access target.
Note: Trace route testing results only for reference, for accurate test route tracking, Pls use professional Ethernet tester.Click to  enter trace route
Input tracking IP address or domain name in the Remote Host IP. Set maximum hop count, normally default is 30.

Link monitor
Click the icon  to open the Link Monitor app. This app is used to see if an IP address is occupied by other network devices. This will avoid new address conflicts
Click “Add” and enter the desired IP address. To test different network segments, click the “Settings” icon on the main menu and go to IP Settings and make the desired changes. Once the desired IP addresses are added to the Link Monitor list, click “Start”. If the IP address status shows a check mark the IP address is occupied. If the IP address status shows an X the IP address is available. Click “Stop” to stop the testing.

Application:

Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will result IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied.

12 V power input test

Connect 12 V power adaptor to tester’s charging port, then click icon “PoE” to enter voltage measurement app ,screen show the current adaptor input voltage and power. Note: the current 12 V input measured power is the battery charging power and the device working power, the measured power will change depending on the different of battery power and backlight brightness.

Warning: Do not allow the device connected with input power over 17 V to tester “12 V IN” port, otherwise it will damage the machine.

Digital Multi-meter (Optional)
Click icon  to enter

2) SYMBOLS:

U: DC Voltage Measuring
A: DC Current Measuring
Ω: Resistance Measuring
 : Diode Testing
U~: AC Voltage Measuring
A~: AC Current Measuring
: Continuity Testing
: Capacitance Measuring

AC/DC Voltage and current measurement state display
Auto- range The Multimeter auto adjust the range by input signal or tested components
Data hold Hold data
Relative measurement

 

Display the relative measurement value

Press the key to change display state

10 A socket In 10A current measurement state ,indicate use 10A socket
Over range The current measurement value over the range, if in the Auto range state, to switch Auto.

 OPERATING INSTRUCTION

DC Voltage Measuring

  1. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack.
  2. Select U, enter the DC voltage measurement.
  3. The tester default Auto range status, by clicking “DC auto range”, press the key to select manual range and restore auto range.

Manual range:

0.000 V -> 6.600 V range
00.00 V -> 66.00 V range
000.0 V -> 660.0 V range
000.0 mV -> 660.0 mV range

AC Voltage Measuring

  1. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack.
  2. Select U ~, enter the AC voltage measurement.
  3. The tester default the status as Auto range, by clicking “AC auto range”
  4. Manual range can be selected, press the key “NEAR” to restore Auto range

Manual range:

0.000V -> 6.600 V range
00.00V -> 66.00V range
000.0V -> 660.0V range
000.0mV -> 660.0 mV range

DC Current Measuring (only manual range)

WARNING! : Shut down the power of the tested circuit, and then connect the meter with the circuit for measurement.

  1. Connect the black test lead to the “COM” jack and the red test lead to the “mA” jack for a maximum of 660mA current. For a maximum of 10A, move the red lead to the 10A jack.
  2. Select A, enter the DC current measurement, the screen display “DC current ”,can select manual range;

Manual range:
0.000mA ->6.6mA range
00.00 mA -> 66.00 mA range
000.0mA -> 660.0 mA range
00.00A -> 10.00 A range (use 10A socket)

Select the range to enter current measurement

Note:

  • When the figure “OL” is displayed, it indicates over range situation and the higher range has to be selected.
  • When the value scale to be measured is unknown beforehand, set the range selector at the highest position.
  • The maximum current of mA socket is 660mA; over-current will destroy the fuse, and will damage the meter.
  • The maximum current of 10A socket is 10A, over-current will destroy the meter, and will damage the operator.
  • In “AC” mode, only can input “AC”, if not, will damage the meter.

Resistance Measuring

WARNING! : When measuring in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have discharged fully.

  1. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack.
  2. To select Ω, enter the Ω measurement
  3. The tester default Auto range status, Press the key manually select range ,Press “NEAR” to restore “Auto range”

Manual range: Connect the red lead to black leads, will display the measure range

000.0Ω -> 660 Ω range
0.000 KΩ -> 6.600KΩ range
00.00 KΩ -> 66.00 KΩ range
000.0 KΩ -> 660.0 KΩ range
0.000 MΩ -> 6.600 MΩ range
00.00 MΩ -> 66.00 MΩ range

Continuity Testing

  1. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack.
  2. To select , enter the continuity test, Connect test leads across two point of the circuit under testing.
  3. If continuity exists (i.e., resistance less than about 50Ω), built-in buzzer will sound.

Diode Testing

  1. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack. (the red lead anode “+” )
  2. To select “”, enter the diode testing.
  3. Connect test red lead across to the anode, the black lead to the cathode of the diode under testing.
  4. Connect test red lead across to the cathode, the black lead to the anode of the diode under testing.
  5. Tested diode will forward the voltage as low as 30 mv and there is sound indication when completing the test.

Capacitance Measuring

  1. Connect the black test lead to the “COM” jack and the red test lead to the “V/Ω” jack.
  2. Select “” to enter, enter the capacitance measurement.
  3. The tester default auto range status, and manual range by press upward and downward key, Auto rang by press the key “NEAR”
    Manual range:

 0.000 nF -> 6.600nF range
00.00 nF ->66.00nF range
000.0 nF -> 660.0nF range
0.000 uF -> 6.600μF range
00.00 uF -> 66.00μF range
000.0 uF -> 660.0μF range
0.000 mF -> 6.600mF range
00.00 mF -> 66.00mF range

Before connect test leads across two sides of the capacitor under measurement, be sure that the capacitor has been discharged fully.

Note:

  1. The capacitance of a capacitor should be tested separately, should not test in the installation of circuit.
  2. To avoid electric shock, be sure the capacitors have been discharged fully before measuring the capacitance of a capacitor.
  3. While testing the capacitance of a capacitor to 660uF, the Max time will be 6.6 seconds, if the capacitor is leaked or damaged, the data can’t be read. The tester will be normal after disconnecting the capacitor.

Manual range and Auto range

When testing, click “Range select” to change the value, click “Auto range” to enter Auto measurement

Data hold

Click “Hold data” to enter, the data be hold, the value is green. Press it again to quit.

Relative value measurement

Click “Relative value” to enter the tester Auto-save the data, the displayed new measurement and relative value is red color. Press it again to quit.The hold function and the relative value be combined in use, the display value is yellow

The meter protection

Voltage protection

You can’t input the voltage which more than 660 V AC, it’s possible to show higher voltage, but it may destroy the inner circuit.

Resistance, Continuity, Diode, PTC component Protection

Wrong input voltage, will auto enter protection state, it is only suitable for short and limit time work. If input voltage over 600 V, the meter gets damage.

mA current fuse range: 250V 1A

If the current over the rated range, fuse will melt to protect the meter .Use the same model to change the fuse, open the battery cover to change.Note: 10A socket without fuse protection, if over the current range.
Wrong using the 10A socket to measure the voltage, will damage the meter.

Optical power meter (Optional)

Click icon   to enter, with five wavelength 1625 nm, 1550 nm, 1490nm, 1310nm, 1300nm, 850nm, linear or nonlinear optical power display, both for optical power testing and Fiber link loss relative measurement. It is necessary tool for installation and maintenance optical fiber communication, cable television and CCTV security system.

Note: Please keep the fiber connector and the dust cap be clean, and clean the detector with the special alcohol.

Data hold

While testing, click “Hold” to data hold, the data will not change. It’s convenient to read. Press again to quit.

 Relative power value (optical link loss) measurement

While testing, set the wavelength for measurement. Click “relative” (difference) to test, the tester Auto save current fiber power value as the base reference value. Input another optical fiber to be measured, the displayed new measurement and relative value is red color. Press it again to quit. Data hold and Relative measuring use together, the data is yellow while the function is effect.

 Visual Fault Locator (Optional)
Click icon to enter

VFL can select four status: “Steady mode”, “Evasive 1 Hz”, “Evasive 2 Hz” and “Time off”. Click button “Steady mode” to enter steady status, click button “Evasive 1Hz” and “Evasive 2Hz, to enter pulse mode, click button “Time off”, VFL is turned off. Timed turn off can select (5 mins, 10 mins, 30 mins, 60 mins and 120 mins). Click “Steady mode”, red laser source emits steady, click again to quit. Click icons “Evasive 1Hz”or “Evasive 2Hz”to enter pulse mode, the red laser source is emitted by a certain frequency, press it again to quit

Audio test

You can test the audio input from audio pickup devices by connecting the audio pickup device to the IP tester with the supplied audio cable.

PoE power output

The IP tester supports PoE (Power over Ethernet) output to an IP camera via the LAN port. Data transmission and 48VDC use the network cable’s 1, 2, 3, and 6 pins to deliver power. If the IP camera supports PoE, you can directly connect to the camera without the use of an external power supply.

Note:

  1. Please make sure the cable connected to the tester’s Lan port is straight-line cable and has no short circuit, otherwise will damage the tester
  2. Before using PoE power output, check the IP camera whether it supports POE powered. Otherwise it will damage the IP camera.
  3. The instrument’s PoE maximum power output is 24 W. If Ultra- high-power load happens, the tester will enter protection mode.

HDMI output

The built in HDMI output port can output live video from an analog or IP camera, recorded files, media files and images to HDTV monitors. Connect an HDMI cable from the IP tester to an HDTV monitor at any time. It supports up to 1080P resolution

DC12V 2A power output

When the IP tester is turned on, the DC 12V power output ON by default. The smaller end of the supplied converter cable connects to the tester’s DC12V/2A OUTPUT and the other end connects to the camera’s power input.

Application

Power output function is mainly used in the camera field demonstration and testing, meanwhile, for some camera installation sites, if there is no power outlet for the adapter to power the camera, the tester can offer temporary power for it. But we do not suggest tester supply power for a long time.
Notice:

  1. Do not input any power into the “DC12/2A OUTPUT” port of the tester
  2. The IP tester’s power output capacity is 2 A. If the IP camera uses more than 2 A, the tester will automatically enter a protection mode
  3. Disconnect all cables from the tester and reboot it to resume using the tester. The IPC tester power output is close to 2A, if the IP camera’s power is over 2V, the tester will auto enter protection mode. Disconnect all the connections of the tester and then connect the tester with power adaptor to resume the tester.
  4. Make sure the tester has a sufficient charge otherwise the tester will not able to provide enough output power

USB 5 V 2A power output

When the tester is turned on, the 12 V DC and 5 V DC power output functions are automatically turned on. If the IP tester is turned off, the 5 V DC USB can still be used to power an external USB device.
NOTE: The USB port is for power only and not data.

 