GAOTek Benchtop Conductivity Ash Meter
This Benchtop Conductivity Ash Meter has resolution of 0.001, 0.01, 0.1, 1, automatic, accuracy: 0.5% F.S, and temperature of 0 to 105°C.
SKU:
GAOTek-CMTM-212
Category: Conductivity Meters with Temperature Measurement
Description
Description
Features
- Professional benchtop conductivity meter is equipped with a 7-inch TFT display
- 1 to 3 points calibration with automatic recognition for conductivity standards
- Cell constant, ref. temp, TDS factor, water compensation modes
- Auto temp compensation corrects conductivity to reference temperature
- Auto-Read function senses and locks the measurement endpoint
- Timed Interval Readings sends the measurement data to a PC or printer
- Limit Alarm automatically alerts when reading exceeds the specified range
- Calibration due alarm prompts user to calibrate the meter regularly
- Calibration report shows the date, time, calibration point and factor
- Password protection prevents the unauthorized calibration and settings
- Expanded memory stores or recalls up to 1000 data sets
- Reset function automatically resumes all settings back to the factory defaults
Technical Specifications
| Conductivity Range | 0 µS/cm to 20.00 µS/cm and 200.0 µS/cm to 2000 µS/cm and 20.00 mS/cm and 200.0 mS/cm |
| Resolution | 0.001, 0.01, 0.1, 1, Automatic |
| Accuracy | ±0.5% F.S. |
| Calibration Points | 1 to 3 Points |
| Calibration Solutions | 10 µS or 84 µS or 1413 µS or 12.88 mS or 111.8 mS |
| TDS Range | 0 mg/L to 10 mg/L and 100 mg/L and 1000 mg/L and 10.00 g/L to 200.0 g/L |
| Resolution | 0.01 and 0.1 and 1 and Automatic |
| Accuracy | ±1% F.S. |
| TDS Conversion Factor | 0.1 to 1.0 (Default 0.5) |
| Salinity Range | 0.00 to 80.00 ppt / 0.00 to 42.00 psu / 0.00 to 8.00% |
| Resolution | 0.01 |
| Accuracy | ±1% F.S. |
| Resistivity Range | 0.00 MΩ to 30.00 MΩ |
| Resolution | 0.01, 0.1, 1, Automatic |
| Accuracy | ±1% F.S. |
| Conductivity Ash Range | 0.00 to 100% |
| Resolution | 0.01, 0.1, 1, Automatic |
| Accuracy | ±1% F.S. |
| Temperature Range | 32 °F to 221 °F (0 °C to 105 °C) |
| Resolution | 0.1°C/°F |
| Accuracy | ±0.9 °F (±0.5 °C) |
| Offset Calibration | 1 Point |
| Calibration Range | Reading ±10 °C/ °F |
| Other Specifications Temperature Compensation | 32 °F to 212 °F (0 °C to 100 °C), Manual or Automatic |
| Temperature Coefficient | Linear (0.0%/°C to 10.0%/°C) / Non-Linear / Pure Water |
| Reference Temperature | 68 °F or 77 °F (20 °C or 25 °C) |
| Cell Constant | 2-Pole Electrodes (K=0.1 / 1 / 10) or 4-Pole Electrode |
| Stability Criteria | Standard / High-accuracy |
| Measurement Modes | Continuous / Auto-Read Measurement Endpoint |
| Timed Interval Readings | 10 or 30 or 60 sec, 10 or 30 Minutes or Off |
| Calibration Due Alarm | 1 to 31 Days or Off |
| High/Low Limit Alarm | Selectable |
| Password Protection | 4 Digits |
| Memory | Stores Up to 1000 Data Sets |
| Output | USB Communication Interface |
| Connector | 6-pin Mini-DIN, 3.5 mm Jack Socket |
| Display | 7-in TFT LCD |
| Power Supply | 12 V DC Power Adapter |
| Environmental Conditions | 32 °F to 122 °F (0 °C to 50 °C), Relative Humidity <80% |
| Dimensions | 9.44 in × 8.66 in × 3.15 in (240 mm × 220 mm × 80 mm) |
| Weight | 3.74 lb. (1.7 kg) |