GAOTek Benchtop Multiparameter Conductivity Meter

GAOTek Benchtop Multiparameter Conductivity Meter is capable of measuring up to 9 water quality parameters, including pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen etc.

SKU: GAOTek-CMSM-222 Category:
Description

Description

Overview

GAOTek Benchtop Multiparameter Conductivity Meter is capable of measuring up to 9 water quality parameters, including pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen etc.

 

Technical Specifications

Ph Range -2.00 pH to 20.00 pH
Ph Accuracy ±0.002 pH
Resolution 0.001, 0.01, 0.1 pH, selectable
Calibration Points Up to 5 points
Calibration Solutions USA (pH1.68/4.01/7.00/10.01/12.45), NIST (pH1.68/4.01/6.86/9.18/12.45), DIN (pH1.09/4.65/6.79/9.23/12.75
Ion Concentration Range 0.001 to 19999 ppm, mg/L, mol/L (Depending on measuring range of Ion selective Electrode)
Ion Concentration Accuracy ±0.5% Full Scale (Monovalent), ±1% Full Scale (Divalent)
Calibration Points 2 to 5 points
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
Mv Range -1999.9mV to 1999.9mV
Mv Accuracy ±0.2mV
Resolution 0.1, 1mV, selectable
Conductivity Range 0 mS/cm to 20mS/cm (Max.200mS/cm)
Conductivity Accuracy ±0.5% Full Scale
Calibration Points Up to 5 points
Calibration Solutions 10uS/cm, 84uS/cm, 1413uS/cm, 12.88mS/cm, 111.8mS/cm
TDS Range 0ppt to 10ppt (Max. 20ppt, depending on factor setting)
TDS Accuracy ±1% Full Scale
TDS Factor 0.1 to 1.0 (Default 0.5)
Salinity Range 0ppt to10ppt (Max.80ppt)
Salinity Accuracy ±1% Full Scale
Salinity Measurement Modes Practical Salinity (PSU) or Seawater Measurement Standard (ppt)
Resistivity Range 0 to 100MΩ
Resistivity Accuracy ±1% Full Scale
Resolution 0.001, 0.01, 0.1, 1, Automatic
Temperature Coefficient 0.0 to 10.0% per °C
Compensation Modes Linear or Pure Water
Cell Constant K=0.1, 1, 10, selectable
Normalization Temperature 68 °F or 77 °F (20 °C or 25 °C)
Dissolved Oxygen Range 0.00 mg/L or ppm to 20.00mg/L or ppm
Resolution 0.01, 0.1mg/L, selectable
Dissolved Oxygen Accuracy ±0.2mg/L (Calibration and measurement under the conditions of same temperature)
% Saturation of Oxygen 0.0% to 200.0%
Accuracy ±2.0%
Salinity Correction 0 g/L to 50g/L
Pressure Correction 8.70 PSI to 16.31 PSI (60.0 kPa to112.5 kPa), 450 mmHg to 850 mmHg
Temperature Range (32 °F to 221 °F) 0 °C to 105 °C
Temperature Accuracy ±0.9 °F (±0.5 °C)
Temperature Calibration Manual
Temperature Compensation 32 °F to 212 °F (0 °C to 100°C), Automatic or Manual;
DO Mode:32 °F to 122°F (0 °C to 50 °C), Automatic
Auto-Off Manual or Automatic (10, 20, 30 minutes after last key pressed, selectable)
Hold Function Manual or Automatic
Stability Conditions Low or High, selectable
Calibration Due Reminder 0 to 30 days
Reset Function Yes
Memory 500 data sets with Date/Time stamping
Output USB Communication Interface
Connector BNC and 6-pin connector
Power Requirements DC 5 V, using AC adapters, 220 V AC/50 Hz
LCD Display Custom dual-display LCD 5.118 in x 4.331 in (130 mm x 110 mm)
Dimensions  8.27 in x 7.40 in 2.36 in (210 mm × 188 mm × 60 mm)
Weight  2.64 lb (1.2 kg)