GAOTek Benchtop PH Meter

The Benchtop PH Meter has a pH range of -2.000 pH to 20.000 pH, accuracy of ± 0.002 pH and 0.1, 0.01, 0.001 pH selectable of resolution.

SKU: GAOTek-BPM-205 Category:
Description

Description

Overview

The Benchtop PH Meter has a pH range of -2.000 pH to 20.000 pH, accuracy of ± 0.002 pH and 0.1, 0.01, 0.001 pH selectable of resolution.

 

Features

  • Equipped with a large backlit LCD display.
  • 1 to 5 points calibration with auto buffer recognition
  • Selectable pH buffer standard or using the custom calibration solutions
  • Automatically calculates and displays electrode slope that helps decide to replace pH electrode
  • Single point offset calibration allows adjusting the displayed value to a known standard
  • Relative and absolute millivolts measurement modes provide accurate ORP readings
  • 2 to 5 points of calibration including eight concentration calibration points can be selected
  • Automatically recognize ion-selective electrodes
  • Direct ion concentration readout simplifies the elaborate measurement process
  • Selectable multiple concentration units include the ppm, mg/L, and mol/L
  • Automatic temperature compensation ensures accurate readings over the entire range
  • Calibration due reminder prompts the user to calibrate the meter regularly
  • The stability indicator automatically shows the current measurement status
  • Auto hold function freezes stable measured value for easy viewing and recording
  • Manual temperature calibration improves the measurement accuracy of the meter
  • Selectable temperature unit meets different application requirements
  • Automatic electrode diagnosis shows zero point offset and slope of the electrode
  • Help message as an operational guide that helps quickly to begin using a meter
  • The system menu allows the setting of 10 parameters
  • The reset feature automatically resumes all parameters back to the factory default settings
  • Expanded memory stores and recalls up to 500 readings
  • Built-in real-time clock stamps stored data to meet GLP standard
  • Stored data can be transferred to a computer by USB communication interface

 

Technical Specifications

Range -2.000 pH to 20.000 pH
Accuracy ± 0.002 pH
Resolution 0.1, 0.01, 0.001 pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN, or User Defined
Range -1999.9 mV to 1999.9 mV
Accuracy ± 0.2 mV
Resolution 0.1, 1 mV, Selectable
Calibration Points 1 point (Only for Relative mV mode)
Calibration Range ± 200 mV
Range 0.001 ppm to 19999 ppm, mg/L, mol/L (Refer to the range of ISE)
Accuracy ± 0.5 % F.S (Monovalent), ± 1 % F.S (Divalent)
Resolution 0.001, 0.01, 0.1, 1
Calibration Points 2 to 5 points
Calibration Solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L
Compensation Mode Manual or Automatic
Hold Function Manual or Automatic
Stability Conditions Low or High
Calibration Due 0 to 31 days
Power Off Manual or Automatic (10, 20, 30 minutes)
Reset Function Yes
Memory Stores up to 500 data sets
Output USB Communication Interface
Connector BNC
Display LCD 5.11 in x 4.33 in (130 mm x 110 mm)
Power Requirements DC5V, using AC adapter, 220 vacs or 50 Hz
Range 0 °C to 105 °C, 32 °F to 221 °F
Accuracy ± 0.5 °C, ± 0.9 °F
Resolution 0.1 °F (0.1 °C)
Calibration Points 1 point
Calibration Range Measured value 50 °F (± 10 °C)
Temperature Compensation 0 °F to 100 °F, 32 °F to 212 °F
Dimensions 8.26 in x 7.40 in x 2.36 in
(210 mm x 188 mm x 60 mm)
Weight 3.30 lb (1.5 kg)