GAOTek Benchtop Water Quality Tester

GAOTek Benchtop Water Quality Tester, 2 points to 5 points calibration, setup menu contains 9 optional parameters.

SKU: GAOTek-BWQT-210 Category:
Description

Description

Overview

GAOTek Benchtop Water Quality Tester, 2 points to 5 points calibration, setup menu contains 9 optional parameters. The meter is suitable for measuring the ion and water hardness. Accuracy: 1% F.S.

 

Features

  • Water hardness mode
  • Ion mode
  • Calibration Due Alarm reminds users to calibrate the meter
  • Stability indicator signals when measurement is deemed stable
  • Auto-Read locks the measurement endpoint for precise results
  • Interval Readings send data to computer or printer automatically
  • Password prevents unauthorized calibration and settings adjustments
  • Memory stores and recalls up to 1000 data sets
  • Transfer stored readings to the computer via USB interface
  • Reset restores settings to factory defaults automatically for convenience

 

Technical Specifications

Ion Range 0.001 to 30000 (Depending on the range of ISE)
Ion Accuracy ±0.5% FS (Monovalent), ±1% FS (Divalent)
Ion Resolution 0.001, 0.01, 0.1, 1
Ion Calibration Points 2 points to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Ion Measurement Units ppm, mg/L, mol/L, mmol/L
Ion Measurement Methods Direct reading, known addition, known subtraction, sample addition, sample subtraction
Water Hardness Range (Concentration) 0.05 mmol/L to 200 mmol/L
Water Hardness Range (English Degree) 0 °e to 1404 °e
Water Hardness Range (CaCO3) 0 mg/L to 19999 mg/L
Water Hardness Range (CaO) 0 mg/L to 11220 mg/L
Water Hardness Range (Ca2+) 0 mg/L to 8000 mg/L
Water Hardness Accuracy ±1% FS
Water Hardness Resolution 0.001, 0.01, 0.1, 1
Water Hardness Calibration Points 2 points to 5 points
Water Hardness Calibration Solutions 0.01 mmol/L, 0.1 mmol/L, 1 mmol/L, 10 mmol/L, 100 mmol/L
mV Range ±2000.0 mV
mV Accuracy ± 0.2 mV
mV Resolution 0.1 mV
mV Calibration Points 1 point
mV Measurement Modes Relative or Absolute mV
Temperature Range 32 °F to221 °F (0 °C to 105 °C)
Temperature Accuracy ±0.9 °F (±0.5 °C)
Temperature Resolution 32.18 °F (0.1 °C), 95.89 °F (-17.72 °C)
Temperature Calibration Points 1 point
Temperature Calibration Range Measured value ±50 °F (10 °C)
Temperature Compensation 32 °F to 212 °F (0 °C to 100 °C), Manual or Automatic
Data Hold Manual or Auto-Endpoint
Stability Criteria Standard or High accuracy
Calibration Due Alarm 1 day to 31 days or off
Interval Readings 10 s, 30 s, 60 s, 10 min, 30 min or off
Password Protection Yes
Reset Function Yes
Memory Stores up to 1000 data sets
Output USB communication interface
Connector BNC
Display 7 in (177.8 mm) TFT LCD
Power DC 12 V, using AC adapter, 220 V AC/50 Hz
Dimensions 9.44 in x 8.66 in x 3.14 in (240 mm x 220 mm x 80 mm)
Weight 3.74 lb. (1.7 kg)