GAOTek Cable Fault Locator
This Cable Fault Locator has the longest testing distance 9.3 mi (62.13 mi for the open-wire line), testing dead zone of 1 m, and resolution of reading 1 m.
SKU:
GAOTek-WTLT-202
Category: Wireless Transmission Line Testers
Description
Description
Technical Specifications
| The Longest Testing Distances | 9.3 mi (15 km) (62.13 mi (100 km) for the open-wire line) |
| Testing Dead Zone | 1 m |
| Resolution Of Reading | 1 m |
| Power Dissipation | 5 VA |
| Environment Temperature | 32 ℉ to 104 ℉ (0 ℃ to 40 ℃) |
| Terminal Temperature | 14 ℉ to 122 ℉ (-10℃ to 50℃) |
| Relative Humidity | 20% RH to 90% RH |
| Dimension | 10.83 in × 8.66 in × 6.3 in (275 mm × 220 mm × 160 mm) |
| Weight | 3.96 lb (1.8 kg) |
| Pathfinders | |
| Operation Mode | Output – fixed frequency intermittent square wave signal |
| Output Power | Pomax ≥ 100 W |
| Output Impedance | 1 Ω to unlimited |
| Output Signal Frequency | 16 kHz |
| Output Signal Amplitude | 15 V to 340 V |
| Pathfinder Transmitter Power Supply | AC 220 V ± 10℅ |
| Fault Locator | |
| Rough Measurement Error | Less than 10% |
| Fixed-Point Error | < ± 10 cm |
| Electromagnetic Channel Gain | > 110 dB (300,000 times) |
| Electromagnetic Channel Receiver Sensitivity | < 5 μV |
| Sound Channel Audio Amplifier Gain | < 120 dB (1 million times when the signal-to-noise ratio is 4:1) |
| 50Hz Power Frequency Rejection | > 40 dB (100 times) |
| Power Consumption | < 120 mA (0.7W) |
| Buried Depth Detection | > ≦ 3 m |