GAOTek Chlorine Fixed Online Cl2 Gas Analyzer

GAOTek chlorine fixed online Cl2 gas analyzer includes RS 485 Modbus digital output and 4 mA to 20 mA analog digital output as well as 2 relay output as standard.

SKU: GAOTek-CGA-216 Category:
Description

Description

Overview

GAOTek chlorine fixed online Cl2 gas analyzer includes RS 485 Modbus digital output and 4 mA to 20 mA analog digital output as well as 2 relay output as standard.  It also provides other signal transmissions like 3 to 4-core cables, Optical fibre networks, Network cables, 3G transmission, Wireless transmission, and Video transmission.

 

Features

  • 4 in (60.96 mm) technical grade display with a pixel up to 320 Pixel x 240 Pixel
  • Three concentration units are available PPM, %VOL, mg/m3
  • Variety signal output models
  • Variety signal transmission is available
  • All software automatic calibration
  • Chinese and English operation models are available
  • User friendly

 

Technical Specifications

Sensor Electrochemical Gas sensor
Detection Pattern Diffusion, pipeline, Circulation, Pumping is available, Online detection
Detection Range 0 ppm to 10 ppm, 50 ppm, 100 ppm, 200 ppm, 500 ppm, 1000 ppm, 2000 ppm, 5000 ppm
Resolution 0.01 ppm (0 ppm to 100 ppm), 0.1 ppm (0 ppm to 1000 ppm), 1 ppm (0 ppm to 5000 ppm)
Detection Accuracy ≤±3% FS
Reaction Time ≤20 s (T 90)
Recovery Time ≤20 s
Linearity error ≤±1% FS
Zero drift ≤±1% (FS / Year)
Repeatability ≤±1% FS
Relay output Two relays output, Contact rating 24 V DC 3 A or 220 V AC 3 A
Explosion Proof Sign Exd II CT6, Certification Number of Explosion-proof CNE x 10.1807
Outputs Analog 4 mA to 20 mA signal, 0 V to 5 V, 0 V to 10 V

Modbus RS 485 signal

Pulse signal or TCP or IP signal, optional

Alarm Setting Two alarm set points
Alarm mode optional Low Alarm-High alarm or High Alarm-High alarm or Low Alarm-Low alarm
Controllers Compatible with DN 3000 or DN 9000, as well as most DCS or PLC systems
IP Rating IP 65
Material Aluminum, Explosion and corrosion-proof
Operating
Pressure
0 Kpa to 200 Kpa
Relative Humidity ≤90%RH, Non-condensing
Operating Voltage 24 V DC (9 V DC to 30 V DC)
Operating
Temperature
-22.00 °F to 122.00 °F (-30 °C to 50 °C)
Dimensions 7.87 in × 6.30 in × 3.15 in (200 mm × 160 mm × 80 mm) (L × W × H)
Weight 3.31 lb (1.5 kg)