GAOTek Conductivity Measuring Instrument

This Conductivity measuring instrument has a resolution of 0.1 pH or 0.01 pH, mV measuring of -1999 mV to 0 to 1999 mV, and IP level IP 54.

SKU: GAOTek-BCM-208 Category:
Description

Description

Features

  • The most versatile pH + conductivity dual parameter measuring instrument
  • It has intelligent functions such as automatic calibration, automatic temperature, compensation, data storage, RS232 output, clock display, function setting and self diagnostic information
  • There are three different measurement modes: stable display mode; timing measurement mode; continuous measurement mode
  • Automatically identify pH standard buffer solutions. There are three series of standard buffer solutions to choose from: European and American series, NIST series and Chinese series
  • Using conductivity measurement technology, using a conductivity electrode with a constant K=1, only one point of calibration can meet the measurement accuracy requirements of 0.5μS per cm to 200 to switchable conductivity, TDS, salinity and resistivity.
  • TDS and salinity are  calculated using polynomials to ensure the conversion accuracy of the full range
  • The instrument carries the product serial number it meets the IP54 dust-proof and splash-proof rating, and the instrument socket is sealed and protected by a silicone cap

 

Technical Specifications

pH Measuring Range -1.99 pH to 19.99 pH
Resolution 0.1 pH or 0.01 pH
Accuracy Electric meter: ± 0.01 pH, supporting: ± 0.02 pH
Input Current ≤ 1 × 10 to 12 A
Input Resistance ≥ 3× 1012 Ω
Stability ± 0.01 pH or 3 h
mV Measuring -1999 mV to 0 to 1999 mV
Range mV or ORP or EH 1 mV
Resolution ± 0.1 % FS
Conductivity Measuring Range (0 to 200) to, divided into five ranges: (0.00 to 20.00)μS per cm (20.0 to 200.0)μS per cm 200 to 2000)μS per cm(2.00 to 20.00)to (20.0 to 200.0)
Resistivity 0 to 100 MΩ·cm
Resolution TDS 0 to 100 g per L
Accuracy Salinity 0 to 100 ppt
Temperature Compensation Range Cell Constant 0.01 or 0.1 or 1 μS per cm 0.01 or 0.1 to Electric meter: ± 1.0% FS, supporting: ±1.50% FS
Ambient Temperature 41 ºF to 95 ºF (5 ℃ to 35 ℃)
Environment Humidity ≤ 85 %
IP Level IP 54 Dust and splash proof
Power Supply DC 9 V or 300 mA
Data Storage 900 set
Measuring Range 32.18 ºF (0.1℃)
Resolution Accuracy 41 ºF to 140 ºF (5℃ to 60℃) range:32.9 ºF ± (0.5℃) Remaining range:32 ºF (± 1℃)
Temperature 50 ºF to 230 ºF (-10 ℃ to 110 ℃)
Dimension 6.29 in x 7.48 in x 2.75 in (160 mm × 190 mm × 70 mm)
Weight 1.94 lb. (0.88kg)