GAOTek Crack Integrated Detector

GAOTek Crack Integrated Detector is mainly used for the accurate detection of bridges, tunnels, buildings, concrete pavement, metal surface and so on.

SKU: GAOTek-CDDL-178 Category:
Description

Description

Overview

GAOTek Crack Integrated Detector is mainly used for the accurate detection of bridges, tunnels, buildings, concrete pavement, metal surface and so on. The system can automatically capture the image of cracks and real-time display crack images and their width data. The image data can be saved automatically.

 

Features

  • Small size and light weight, including the battery weight is only 0.75kg.
  • Built-in domestic and foreign industry standards: The instrument has 11 national standards built-in, compatible with European standards.
  • EN12668-1: 2010, which is convenient for setting various DAC and AVG curve parameters.
  • Accurate flaw detection High sensitivity.
  • High-precision thickness measurement. Coating can be penetrate
  • High-resolution 5.0-inch (800 × 480) widescreen true-color TFT LCD display.
  • Recording function and mass data storage.
  • HDMI interface Support for teaching use
  • WIFI communication Query flaw detection results anytime and anywhere
  • Low power consumption design Reliable function.

 

Technical Specifications

Valve off/incoming wave/lost wave
DAC, AVG Function DAC curve, AVG curve
Attenuator Error Every 12 dB±1 dB
Vertical Linear Error ≤3%
Horizontal Linear Error ≤0.5%
Dynamic Range ≥30 dB
Flaw Deterction Margin ≥65(2.5Z20N probe) dB
Operating Voltage 12V(battery, DC)
Working Frequency Range 0.5 MHz to 20 MHz
Plus Width Square wave width 30 to 1000ns, step0.1ns
Detection Range 0 in to 551.18 in (0 mm to 14000 mm) (steel longitudinal wave)
Pules Displacement 1.77 in to 39.4 in (-45 mm to 1000 mm) (steel longitudinal wave)
Material Sound Velocity 300 m/s to 15000 m/s
Valve off/incoming wave/lost wave
DAC, AVG Function DAC curve, AVG curve
Attenuator Error Every 12 dB±1 dB
Vertical linear Error ≤3%
Horizontal Linear Error ≤0.5%
Dynamic Range ≥30 dB
Flaw Deterction Margin ≥65 (2.5Z20N probe) dB
Operating Voltage 12 V (battery, DC)
Physical Dimension 7.09 in x 5.12 in x 1.57 in (180 mm x 130 mm x 40 mm)
Storage Expansion TF card, mass storage