GAOTek Cyanide Ion Meter
This Cyanide Ion Meter has a calibration solution 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, calibration due 0 day to 31 days and accuracy ± 0.2 mV.
SKU:
GAOTek-OIM-204
Category: Outdoor Ion Meters
Description
Description
Features
- High performance portable cyanide ion meter is equipped with a large LCD
- 2 to 5 points calibration from low to high concentrations
- Direct ion concentration readout simplifies the elaborate measurement process
- Automatic Temperature Compensation provides accurate reading over the entire range
- Calibration Due Reminder prompts user to calibrate the meter regularly
- Stability indicator automatically shows current measurement status
- Auto-Hold function freezes stable reading for easy viewing and recording
- Manual temperature calibration improves the measurement accuracy of the meter
- mV measurement mode allows the user to check the performance of the ion selective electrode
- Automatic electrode diagnosis shows the slope of the sensor
- Help message as an operational guide that helps you quickly begin using the meter
- Built-in real-time clock stamps stored data to meet GLP standards
- Stored data can be transferred into a computer by USB communication interface
- Multi-mode power scheme (battery, power adapter, computer’s USB port) ensures that use the meter smoothly
Technical Specification
| Range | 5 × 10-6 M to 0.01 M, 0.2 ppm to 260 ppm |
| Accuracy | ± 1 % F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 points to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol per L, mg per L |
| Range | -1999.9 mv to 1999.9 mV |
| Accuracy | ± 0.2 mV |
| Resolution | 0.1 mV |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 days to 31 days |
| Power Off | Manual or Automatic (10 minutes, 20 minutes, 30 minutes) |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3 V × 1.5 V AA Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Range | 32 °F to 221 °F (0 °C to 105 °C) |
| Accuracy | ± 0.9 °F (± 0.5 °C) |
| Resolution | 0.1 °F (0.1 °C) |
| Calibration Range | Measured value ± 50 °F (± 10 °C) |
| Temperature Compensation | 32 °F to 212 °F (0 °C to 100 °C) |
| Dimensions | 6.69 in x 3.34 in x 1.18 in (170 mm × 85 mm × 30 mm) |
| Weight | 0.66 lb (0.3 kg) |