GAOTek Hand-Held Oscilloscope

GAOTek hand-held oscilloscope is compact and rugged and is ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications.

GAOTek-MSO-125

Description

Overview

GAOTek hand-held oscilloscope is compact and rugged and is ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. Features innovative functions that help technicians troubleshoot faster for quicker results and to keep their systems running smoothly. Additionally, triggering displays waveforms without having to adjust amplitude, time base, and trigger settings.

 

Technical specification

Frequency Response – DC Coupled Without probes and test leads (with BB120): DC to 20 MHz (-3 dB)
With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB)
With VP41 10:1 probe: DC to 20 MHz (-3 dB)
Frequency Response – AC Coupled (LF Roll Off) Without probes and test leads: <10 Hz (-3 dB)
With STL 20-IV 1:1 shielded test leads: <10 Hz (-3 dB) With VP41 10:1 probe: <10 Hz (-3 dB)
Rise Time, Excluding Probes, Test Leads <17.5 ns
Input Impedance Without probes and test leads: 1 MΩ or 20 pF
With BB120: 1 MΩ or 24 pF
With STL120-IV 1:1 shielded test leads: 1 MΩ or 230 pF, With VP41 10:1 probe: 5 MΩ or 15.5 pF
Sensitivity 5 mV to 200 V/div
Analog Bandwidth Limiter 10 kHz
Display Modes A, -A, B, -B
Maximum Input Voltage A and B Direct, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 V rms maximum voltage
With BB120: 600 Vrms
Maximum Floating Voltage, from any Terminal to Ground 600 V rms CAT IV, 750 V rms up to 400 Hz
Scope Modes Normal, single, roll
Ranges (Normal) Equivalent sampling: 20 ns to 500 ns/div
Real-time sampling: 1 μs to 5 s/div
Single (real-time): 1 μs to 5 s/div
Roll (real-time): 1 s to 60 s/div
Sampling Rate (for Both Channels Simultaneously) Equivalent sampling (repetitive signals): up to 4 GS/s
Real-time sampling 1 μs to 60 s/div: 40 MS/s
Screen Update Free run, on trigger
Source A, B
Sensitivity A and B At DC to 5 MHz: 0.5 divisions or 5 mV
At 40 MHz: 4 divisions
Slope Positive, negative
DC Voltage (V DC) Ranges: 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy: ±(0.5% +5 counts)
Common mode rejection (CMRR): >100 dB at DC, >60 dB at 50 Hz, 60 Hz, or 400 Hz
Full scale reading: 5000 counts
True RMS Voltages (V AC and V AC + DC) Ranges: 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled)
DC to 60 Hz (V AC + DC): ±(1% +10 counts)
1 Hz to 60 Hz (V AC): ±(1% +10 counts)
Accuracy for 5% to 100% of range (AC or DC coupled): 60 Hz to 20 kHz: ±(2.5% +15 counts)
DC rejection (only V AC): >50 dB
Common mode rejection (CMRR): >100 dB at DC; >60 dB at 50 Hz, 60 Hz, or 400 Hz
Full-scale reading: 5000 counts, reading is independent of any signal crest factor
Peak Modes: Maximum peak, minimum peak, peak to peak, Ranges: 500 mV, 5 V, 50 V, 500 V, 2200 V
Accuracy: Maximum peak or minimum peak: 5% of full scale; peak to peak: 10% of full scale
Full-scale reading: 500 counts
Frequency Ranges: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 50 MHz
Frequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset, Accuracy at 1 Hz to 1 MHz: ±(0.5% +2 counts)
Full-scale reading: 10,000 counts
RPM Maximum reading: 50 kRPM
Accuracy: ±(0.5% +2 counts)
Pulse Width Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset, Full-scale reading: 1000 counts
Amperes With current clamp
Ranges: same as V DC, V AC, V AC + DC, or peak
Scale factors: 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
Accuracy: same as V DC, V AC, V AC + DC, or peak (add current clamp uncertainty)
Decibel 0 dBV: 1 V
0 dBm (600 or 50 Ω): 1 mW referenced to 600 or 50 Ω
dB on V DC, V AC, or V AC + DC
Full scale reading; 1000 counts
Crest Factor Range: 1 to 10
Full scale reading: 90 counts
Waveform Display Vertical: 10 div of 40 pixels
Horizontal: 12 div of 40 pixels
Maximum Input Voltage A and B Direct on input or with leads: 600 Vrms CAT IV for derating
With banana to BNC adapter BB120: 600 Vrms for derating
Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz
Display Type: 5.7 in (14.4 cm) color active matrix TFT
Resolution: 640 pixels x 480 pixels
Temperature Battery operation: 32 °F to 104 °F (0 °C to 40 °C)
Power adapter operation: 32 °F to 122 °F (0 °C to 50 °C)
Storage: -4 °F to 140 °F (-20 °C to 60 °C) non-condensing
Humidity (Operating) At 32 °F to 50 °F (0 °C to 10 °C): non-condensing
At 50 °F to 86 °F (10 °C to 30 °C): 95%
At 86 °F to 104 °F (30 °C to 40 °C): 75%
At 104 °F to 122 °F (40 °C to 50 °C): 45%
Power Battery power: Rechargeable Li-Ion 10.8 V
Operating time: 7 hrs with 50% backlight brightness
Charging time: 4 hrs with the test tool off, 7 hrs with the test tool on
Allowable ambient temperature: 32 °F to 104 °F (0 °C to 40 °C) during charging
Dimensions 10.2 in x 5.2 in x 2.15 in (259 mm x 132 mm x 55 mm)
Weight 3.2 lb (1.4 kg) including battery pack