Description

Overview

GAOTek hydrogen chloride gas leak detector continuous measurement hydrogen chloride and gas detector with hydrogen leak detector alarm system with built-in pump.

 

Features

  • Optional fall alarm function to ensure safety of underground workers is more secure
  • Optional 8G large-capacity memory card, support one-click download function, if with 4 kinds of gases Storage interval time is 5s, can be used for 7 years and this function is standard provided if the detector with optional air sampling
  • Optional PC storage software download, analysis storage data
  • Optional external Bluetooth printer.

 

 Technical Specifications

Gas detected Hydrogen chloride hcl
Detection principle Catalytic combustion principles
Measure range 0 ppm – 5000 ppm,10000 ppm, 5 % Vol, 50 % Vol, 100 %  Vol, 100 % LEL
Resolution 0.01 % VOL
Sampling method Built-in stable flow pump, flow range: 0 ML/Min – 500 ML/Min
Modular structure Can detect up to 1- 4 kinds of gases
Concentration unit ppm, mg/m3, % VOL, % LEL, can be switched by one button
Display 3.5 – inch color display, resolution 320 x 480
Display mode, Multiple display modes select-able: multi-channel data mode,
multi-curve mode, single channel + single curve mode
Print Built-in printer or external Bluetooth printer (optional with extra charge)
Battery capacity 3800 mas
Charging interface Usb charging interface, 5 V/ 2 A standard charger
Filter device Equipped with a multi-layer filter to efficiently filter oil, water and dust.
Wireless network Bluetooth (with print function), zigbee, lora + (relay dtu), dtu (optional with extra charge)
Network frequency Lora (470 m), dtu (2.4 g)
Wireless trans. distance Lora (1.6 km), dtu (unlimited)
Precision 2 % fs
Response time ≤ 8 s
Repeatability ≤ ± 1%
Zero shift ≤ ± 1 % (f.s / year)
Working humidity 0 %  RH – 95 % RH (no condensation) (high humidity can be selected with filter drying device)
Explosion-proof Exic ii ct3 gc
Recovery time ≤ 10 s
Linearity error ≤ ± 1 %
Temperature and humidity detection range Temperature: – 20 °C to 251 °C (- 4 °F to 122 °F), resolution: 32.18 °F (0.1 °C)

Humidity: 0 % Rh to 99 % Rh, resolution: 1 % Rh (optional)

Dimensions 10.62 in x 2.95 in x 1.61 in (270 mm x 75 mm x 41mm)
Weight 0.88 lb (0.4 kg)