GAOTek Monitoring Spectrum Analyzer

GAOTek monitoring spectrum analyzer is essential popular versions of series receivers, with one receiver port and one signal source port.

GAOTek-SA-135

Description

Overview

GAOTek monitoring spectrum analyzer is essential popular versions of series receivers, with one receiver port and one signal source port. it supports 100 kHz to 4 GHz and supports 100 kHz to 6 GHz. The device uses precision SMA connectors made of stainless steel.

 

Features

  • Frequency range of 100 KHz to 6 GHz
  • Noise figure 13 dB (typical)
  • Maximum level 20 dBm
  • Real-time bandwidth 15 MHz (local display)
  • Real-time bandwidth 40 MHz (PC software)
  • 100% POI: 210 μs (accurate measurement)
  • Search speed: 2 Ghz or s
  • Typical uncertainty 1.5 dB
  • Endurance time: 4 hrs
  • 6 dm volume (0.6 L volume)
  • Net weight about 2 lb (900 g)

 

Technical specification

Items Min. Typical Max. Note or Condition
Port DC withstand voltage 10 V 15 V RF port
External DC supply 10.5 V 26 V 5.5 or 2.5 round port
voltage 5.0 V 20 V TYPE C port
External DC supply 2.0 A 2.5 A 5.5 or 2.5 round port
current 1.5 A 3 A TYPE C port
Battery voltage 6.5 V 8.5 V Batteries not quickly replaceable
Battery capacity 50 Wh 18650 x 4
14 W 16 W 20 W 12 V power supply input,
(Volume, monitor brightness 30%) 4 W battery charging, running
Endurance time 4 hr Battery powered, stop working
Power-off power consumption 500 W 1 mW Battery powered
Stored power time 1 a 2 a 7.5 V initial battery voltage
Speaker power 2 W 4 W
Audio output power 1 W 1.5 W Impedance 40
MIC input sensitivity 50 mV Impedance 6000
Barometer measuring range 300 hPa 1100 hPa
Manometer uncertainty 0.5 hPa Control component temperature 104 ⁰F (40 °C)
Inclinometer uncertainty 33.8 °F (1 °C) Calibrated
Magnetic compass uncertainty 32 °F (0 °C) 41 °F (5 °C) 104 °F (40 °C) Calibrated
-40 °F (-40 °C) 122 °F (50 °C) Normal range
40 °F (-40 °C) 158 °F (70 °C) Allowable range
32 °F (0 °C) 95 °F (35 °C) Short term storage
Ambient temperature The internal temperature of the device must not be higher than the Long term storage
upper limit of the allowable temperature range of the battery; the low
temperature limit within the above temperature range is determined by
the lowest usable temperature of the battery. The maximum
Relative humidity 0% temperature of CPU is 212 °F (100 °C) 95% Working; short term storage
Waterproof performance Level 0 Not waterproof
Anti-drop (basically intact function, 11.81 in (30 cm) Without sheath
allow appearance damage) 3.28 ft (1.2 m) With sheath
Seismic 20 Hz, 5 G, 30 min in any direction With protruding parts
Volume 7.40 in x 4.33 in x 1.53 in (188 mm X 110 mm X 39 mm) 6.97 in x 4.02 in x 

1.26 in (177 mm x 102 mm x 32 mm)

Without protrusions
N.W. 2.00 lb (908 g) 2.09 lb (950 g) Main unit with battery

Reviews