Description
Overview
GAOTek monitoring spectrum analyzer is essential popular versions of series receivers, with one receiver port and one signal source port. it supports 100 kHz to 4 GHz and supports 100 kHz to 6 GHz. The device uses precision SMA connectors made of stainless steel.
Features
- Frequency range of 100 KHz to 6 GHz
- Noise figure 13 dB (typical)
- Maximum level 20 dBm
- Real-time bandwidth 15 MHz (local display)
- Real-time bandwidth 40 MHz (PC software)
- 100% POI: 210 μs (accurate measurement)
- Search speed: 2 Ghz or s
- Typical uncertainty 1.5 dB
- Endurance time: 4 hrs
- 6 dm volume (0.6 L volume)
- Net weight about 2 lb (900 g)
Technical specification
Items | Min. | Typical | Max. | Note or Condition |
Port DC withstand voltage | 10 V | 15 V | RF port | |
External DC supply | 10.5 V | 26 V | 5.5 or 2.5 round port | |
voltage | 5.0 V | 20 V | TYPE C port | |
External DC supply | 2.0 A | 2.5 A | 5.5 or 2.5 round port | |
current | 1.5 A | 3 A | TYPE C port | |
Battery voltage | 6.5 V | 8.5 V | Batteries not quickly replaceable | |
Battery capacity | 50 Wh | 18650 x 4 | ||
14 W | 16 W | 20 W | 12 V power supply input, | |
(Volume, monitor brightness 30%) | 4 W | battery charging, running | ||
Endurance time | 4 hr | Battery powered, stop working | ||
Power-off power consumption | 500 W | 1 mW | Battery powered | |
Stored power time | 1 a | 2 a | 7.5 V initial battery voltage | |
Speaker power | 2 W | 4 W | ||
Audio output power | 1 W | 1.5 W | Impedance 40 | |
MIC input sensitivity | 50 mV | Impedance 6000 | ||
Barometer measuring range | 300 hPa | 1100 hPa | ||
Manometer uncertainty | 0.5 hPa | Control component temperature 104 ⁰F (40 °C) | ||
Inclinometer uncertainty | 33.8 °F (1 °C) | Calibrated | ||
Magnetic compass uncertainty | 32 °F (0 °C) | 41 °F (5 °C) | 104 °F (40 °C) | Calibrated |
-40 °F (-40 °C) | 122 °F (50 °C) | Normal range | ||
40 °F (-40 °C) | 158 °F (70 °C) | Allowable range | ||
32 °F (0 °C) | 95 °F (35 °C) | Short term storage | ||
Ambient temperature | The internal temperature of the device must not be higher than the | Long term storage | ||
upper limit of the allowable temperature range of the battery; the low | ||||
temperature limit within the above temperature range is determined by | ||||
the lowest usable temperature of the battery. The maximum | ||||
Relative humidity | 0% | temperature of CPU is 212 °F (100 °C) | 95% | Working; short term storage |
Waterproof performance | Level 0 | Not waterproof | ||
Anti-drop (basically intact function, | 11.81 in (30 cm) | Without sheath | ||
allow appearance damage) | 3.28 ft (1.2 m) | With sheath | ||
Seismic | 20 Hz, 5 G, 30 min in any direction | With protruding parts | ||
Volume | 7.40 in x 4.33 in x 1.53 in (188 mm X 110 mm X 39 mm) | 6.97 in x 4.02 in x
1.26 in (177 mm x 102 mm x 32 mm) |
Without protrusions | |
N.W. | 2.00 lb (908 g) | 2.09 lb (950 g) | Main unit with battery |
Reviews