Technical Specifications
Gas Detected | Hydrogen/ H2 |
Customized Support | OEM, ODM |
Detection principle | Electrochemical /Catalytic combustion |
Sampling Method | Internal pumping |
Measure Range | 0 PPM to 1000 PPM, 0% LEL to 100% LEL |
Resolution | 1 ppm, 1% LEL |
Precision | ≤±2% FS except for special gases |
Data record | Can store 100,000 sets data, the storage interval is adjustable from 5 to 3600 seconds, data can be exported, with data cable |
Response Time | ≤10 S |
Repeatability | ≤±1% |
Zero shift | ≤±1% (F.S/year) |
Recovery Time | ≤10S |
Linearity error | ≤±1% |
Display | monochrome graphics (160 x 96), screen can be automatically flipped |
Operating language | Chinese/English or customized |
Gas unit | %VOL, PPM, mg/m3 |
Temperature | -4 oF to 122 oF (-20 ℃ to 50 ℃) |
Humidity | 0% RH to 90% RH |
Explosion-Proof | IECEx: Ex IA IIC T4 Ga ATEX: II 1G Ex IA IIC T4 Ga |
Certification | IECEX, EMC, ATEX, CE, ISO9001 |
Degree of protection | IP 67 |
Battery | 3.7 V 2200 mA (Lithium Polymer) |
Alarm mode | Sound, light, vibration |
Environmental pressure | 12.47 PSI to 15.37 PSI (86 Kpa to106 Kpa) |
Dimensions | 6.18 in x 3.32 in x 2.34 in (157 mm x 84.5 mm x 59.5 mm) |
Weight | 0.80 lb (365 g) |