Ultrasonic Liquid Flow Meter with Area Velocity Method – GAOTek
GAOTek Ultrasonic Liquid Flow Meter uses the principle of “area velocity method” to measure the open channel flow.
SKU:
GAOTek-NBED-196
Categories: NB-IoT End Devices, Ultrasonic Liquid Flow Meters
Description
Description
Overview
GAOTek Ultrasonic Liquid Flow Meter uses the principle of “area velocity method” to measure the open channel flow. The system has a built-in open channel flow model, which uses the single-point flow velocity method combined with hydrological fluids to deduce the average flow velocity of the river channel through the single-point flow velocity and calculates the water flow in combination with the water level and the cross-sectional area of the water flow.
Features
- The measurement range is large (velocity range is 0.01-10m/s), and the flow measurement is not affected by the return water on the tributary surface
- The structural design of the flow rate sensor conforms to fluid mechanics, with a small size and convenient installation. The standard channel can be installed directly without modification, and the construction cost is low
- The measurement signal is stable and less affected by the channel water flow
- It can display the channel liquid level, flow rate, instantaneous flow and cumulative flow at the same time
- EEPROM is used to store the accumulated flow, and the data can be stored for a long time after power failure
- Large-screen dot matrix display, not only in Chinese, but also with graphics, which is convenient for operation and flow analysis
- Optional real-time display of flow velocity curve and graphic software, which is convenient for analysis and research of water flow
- With RS485 communication port, it can realize remote data transmission
- Portable with data storage function, easy to analyze the measurement situation
Technical Specifications
| Measurement Accuracy | Flow rate 1.0% R liquid level +0.5% R flow rate +2.5% R |
| Measurement Range | Velocity range 0.01 m/s to 10 m/s |
| Applicable Channels | Rectangular channel, trapezoidal channel, custom-shaped channel width 2 0.2 m channel depth 2 0.1 m |
| Display Content | Flow velocity (m/s), liquid level (m), instantaneous flow (m3/h), cumulative flow (m) |
| Power Consumption | DC 12 V or 24 V power supply, the supporting system is less than 5 W AC 220 Vpower supply, the supporting system is less than 20 W |
| Protection Class | Sensor IP68: converter: IP65 |
| Data Communication | RS485: Modbus protocol GPRS4G: UDP protocol, TCP protocol NB-iot: UDP protocol, TCP protocol, CoAP protocol |