Industrial Temperature Multichannel Data Logger with LCD display- GAOTek

Industrial Temperature Data Logger by GAOTek enables multi-channel temperature monitoring, real-time data logging, and reliable process control for industrial environments.

SKU: GAOTek-HTDL-244 Category:
Description

Description

Features

  • Up to 128 channels of data acquisition test
  • Multiple test units can be measured simultaneously
  • Each test unit can be freely plugged in and out
  • Universal input: current, voltage, thermal resistance, thermocouple, pressure
  • Basic accuracy: 0.2% F.S
  • 7-inch color LCD screen with touch screen, display resolution is 800×480
  • Plug and play keyboard and mouse
  • Temperature compensation function (TC)
  • Can output channel level, board level, whole machine level comparison and sorting results (overlimit, qualified and alarm)
  • Screen information is stored in USB flash drive
  • Data saving function facilitates real-time saving of measurement results
  • Automatically upgrade the instrument operating software via USB HOST
  • Flexible and convenient file operating system
  • Handler interface for online operation
  • RS232, USB HOST, USB Device, LAN, convenient for data communication with PC and remote control of the instrument

 

Technical specifications

Parameters Details
Display 7-inch TFT LCD 800*48 (VGA)
Principal cache capacity 4G
Expanded Memory USB flash
 

Comm.

RS-232/RS-485/USB/GP1B/Zigbee (Standard RS232, others optional)
Maximum number of input and output points Input 128 points (up to 128 points when not in use)
 

Output

 

32 points

 

Networking

FPI terminal/FTP server.SMTP terminal (E-mail sending), HTTP server (Web server)

DHCP terminal SNTP server SNTP terminal, ModbusTCP (terminal

server) ModbusRTU (active/slave)

Withstand voltage Power port-FG port between boxes 8OOVAC (50/60Hz) 1 min.
Insulation resistance Power port-FG port between boxes More than 5MΩ(500VDC)
Touch screen Force Less than 0.8N
Life More than 10 million times
Backlight life About 75000 hour
 

Rated

Power supply voltage (90-240AC±10%) or (24VDC±10%), Fluctuation below 10% (P-P)
Maximum current

consumption

 

Less than 0.45A

 

Measuring parameter

Thermal resistor, thermoelectric corner, voltage, current, (humidity,

pressure, flow)

 

 

 

Input type

• DC current:(4-20)mA, (0-10)mA. (0~20)mA

• DC voltage (1-5)V, (0-5)V, (0-10) V,(l-10)V,<l-100)V

• Thermal resistor:Pt100( 3-wire)

• Thermocouple:K, S. R, B, N, E, J, T, cu50

• Temperature&Humidity:Temperature-20~110℃, Humidity 20%~98%

Optional: AM2001 Humidity module(3%,condition:at 25℃,60%RH.Other condition accuracy is 5%)

Measuring accuracy (Temperature) 0~1000℃: ±(reading*O 5%+1)℃, -100~0℃: ±(reading*0.5%+2)℃;
Channel 8ch,16ch,24ch,32ch,40ch,48ch,64ch, customized can be 128ch
Display resolution 1mV     0.01℃
U disk storage Yes
Live test 300V
Scanning speed 1S
Curve drawing Real-time curve, historical curve
Communication interface RS232 or USB
Supporting software 2023vers. software
Alarm mode One public alarm (relay output) (optional)
Voltage output Internal independent power supply output
Single screen display 32 channels
Temperature correction Yes
Terminal type M3 screw type
Other functions Calendar function, clock function, mouse, plated and plug-and-play,.
Dimensions (Height*Width*Depth) 129*290*300mm; Machine weight: about 5kgs
Accessories Standard configuration: K-type thermocouples (2 meters/piece); Data collection software

 

 

Analog Input Specifications
Item content
Input type Photoelectric relay scanning mode, full channel insulation input, balanced

input

Input terminal type M3 screw type
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring range

Voltage 0.01mV- 100V F.S.(full range ) Highest resolution 1μV
Thermal resistor Type:PT100
Thermocouple Type : K, S. R, B, N, E, J, T
Temperature resolution:0.01℃
Humidity Digital signal input (Rutorotronic precision 0.8%) (domestic high precision

1.5%)

Current 0.01 mA -20.00mA
Sample rate 1s (full channel)
Temperature (thermocouple) Type Measuring                         temperature

range       (TS:     measuring temperature)

Measurement accuracy
R 0≤TS≤100℃ ±5.2℃
100<TS≤300℃ ±3.0℃
300<TS≤1600℃ ±(0.05% of rdg.+2.0℃)
S 0≤TS≤100℃ ±5.2℃
100<TS≤300℃ ±3.0℃
300<TS≤1760℃ ±(0.05% of rdg.+2.0℃)
B 400≤TS≤600℃ ±3.5℃
600<TS≤1820℃ ±(0.05% of rdg.+2.0℃)
K -200<TS≤0℃ ±(0.05% of rdg.+2.0℃)
0<TS≤1370℃ ±(0.05% of rdg.+1.0℃)
E -200≤TS≤-100℃ ±(0.05% of rdg.+2.0℃)
-100<TS≤800℃ ±(0.05% of rdg.+1.0℃)
T -200≤TS≤-100℃ ±(0.5% of rdg.+1.5℃)
-100<TS≤400℃ ±(0.1% of rdg.+0.5℃)
J -200≤TS≤-100℃ ±2.7℃
-100<TS≤100℃ ±1.7℃
100<TS≤1100℃ ±(0.05% of rdg.+1.0℃)
N -200≤TS<0℃ ±(0.1%of rdg.+2.0℃)
0≤TS≤1300℃ ±(0.1% of rdg.+1.0℃)
Standard contact compensation accuracy ±0.5℃
PT100 -100<TS≤100℃ ±0.2℃ (must be notified in advance)
A/D Converter mode:ΔΣ mode,16Bit(Effective resolution: ±1/40000)
Maximum input voltage Between input

Terminals +/-

-110V~100V:p-p
Between channel

(1-1/(-1)

60Vp-p
Between input

terminal and GND

60 Vp-p
Maximum voltage(withstand

voltage)

Between channel 350Vp-p(Within 1 minute)
Between input

terminal and GND

350Vp-p(Within 1 minute)