Thermocouple Calibrator with Temp Select (Soure measure)
Thermocouple Calibrator with Temp Select (Soure measure)

GAOTek Thermocouple Calibrator with Temperature Select (Source measure)

ID: GT00VU00ZX
Category:

USD


Overview

GAOTek Thermocouple Calibrator with Temperature Select (Source measure) is designed to measure in units of °C, °F or mV using a thermocouple minijack and can be used for calibrating the thermocouple device. It supports the mV input and output units so that the calibrator can be used with any thermocouple type by making manual calculations. The Calibrator is also in compliance with standards CE / ETL / RoHS. It is shock resistance, highly cost-effective and is suitable for lab applications.


Key Features

  • Thermocouple standard NIST 175 °C
  • Thermocouple scales ITS-90
  • Storage Temperature ranges from 104 °F ~ 140 °F (40 °C ~ 60 °C)
  • Operating Temperature from 50 °F ~ 131 °F (10 °C ~ 55 °C)
  • Maximum  Operating Altitude is 3000 meters
  • Temperature coefficient : ±0.005 % of range per °C for the temperature range 14 °F ~ 64.4 °F (-10 °C ~ 18 °C) and 82.4 °F ~ 131 °F (28 °C ~ 55 °C)
  • Vibration : Random 2G , 5 Hz ~ 500 Hz
  • Shock : 1 Meter drop test
  • Optional °C / °F Temperature Unit Selection
  • Low Battery Display

Technical Specifications

Thermocouple Type Temperature Ranges Display Resolution
J -328 °F ~ 2192 °F (-200 °C ~ 1200 °C) 0.1 °C or °F
K -328 °F ~ 2498 °F (-200 °C ~ 1370 °C) 0.1 °C or °F
T -328 °F ~ 752 °F (-200 °C ~ 400 °C) 0.1 °C or °F
E -200 °F ~ 950 °C (-328 ~ 1742 °F) 0.1 °C or °F
R  -4 °F ~ 3182 °F (-20 °C ~ 1750 °C) 1 °C or °F
S -4 °F ~ 3182 °F (-20 °C ~ 1750 °C) 1 °C or °F
B 1112 °F ~ 3272 °F (600 °C ~ 1800 °C) 1 °C or °F
N -418 °F ~ 2372 °F (-250 °C ~ 1300 °C) 0.1 °C or °F
Millivolt Measure and Source (Maximum Input Voltage: 30V)
Mode Range Resolution Accuracy
mV -10 mV ~ 75 mV 0.01 mV ± (0.02 % + 2 Dgt)
Temperature Measure and Thermocouple Simulate (Maximum input Voltage: 30V)
Thermocouple Type Resolution Error Reference Junction Error
J, K, T, E, N 0.1 °C or °F ±(0.3 °C + 10 μV) ± 0.2 °C
R, S, B 1 °C or °F ±(0.3 °C + 10 μV) ± 0.2 °C
J, K, T, E, R, S, B, N Standard: NIST 175
Scale: ITS-90
Storage Temperature 104 °F  ~ 140 °F (40 °C ~ 60 °C)
Operating Temperature 50 °F ~ 131 °F (10 °C ~ 55 °C)
Maximum Input Voltage 30 V
Operating Altitude 3000 meters maximum
Relative Humidity 95% [50 °F to 86 °F (10 °C to 30 °C)] /

75% [86 °F to 104 °F (30 °C to 40 °C)] /

45% [104 °F to 122 °F (40 °C to 50 °C)] /

35% [122 °F to 131 °F (50 °C to 55 °C)]

 Vibration Random 2G , 5 Hz ~ 500 Hz
Temperature Coefficient 0.0 5 × specified accuracy per °C for temperature ranges:

50 °F to 16.4 °F (10 °C to 18 °C) and

82.4 °F to 131 °F (28 °C to 55 °C)

Shock 1 Meter drop test
Power Requirements  Single 9V battery (ANSI/ NEDA 160 4A or IEC 6LR61)
Size 7.48 in (L) ×  3.5 in (W) × 1.65 in (H)

(190 mm (L) × 89 mm (W) × 42 mm (H))

Weight Approx. 12.94 oz. (367 g)

Additional Information

Explanation of International Symbols

 The following symbols are used on the calibrator .

Symbol Meaning
  Earth Ground
  —–

Operation:

 Measuring a Thermocouple

  1. Input
  2. Shows TC type select.
  3. Press to select ON or OFF.
  4. Press to select TC type or mV.
  5. Press so that INPUT is on the display.
  6. TC wire and mini plug of same type as selected.
  7. Press to toggle °C or °F.

Simulating a Thermocouple

  1. Output
  2. Shows TC type select.
  3. Press to select ON or OFF.
  4. Press to select TC type or mV.
  5. Press so that OUTPUT is on the display.
  6. Press to step u p / down 10° or 1 mV.
  7. Press to toggle °C or °F
  8. Press to scroll up/down 0.1° or 0.01 mV. Hold down to scroll faster.
  9. TC wire and mini plug of same type as selected.

Maintenance

If the calibrator needs repair, contact your Service Center. If the calibrator is under warranty, see the warranty statement for terms. If the warranty has lapsed, the calibrator will be repaired and returned for fixed fee. Contact your Service Center for information and price.

Cleaning

Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents.

Calibration

Calibrate your calibrator once a year to ensure that it performs according to its specifications.

Replacing the Battery

When the symbol appears on the display, replace the battery with a 9V alkaline battery.

Replacing the Fuse

Fuse is probably blown if in the input mode, the calibrator always reads OL, even with a thermocouple connected.

Safety Information

 WARNING         

To avoid possible electric shock or personal injury:

  • Never apply more than 30 V between the TC terminals, or between either TC terminal and earth ground.
  • Make sure the battery door is closed and latched before you operate the calibrator.
  • Remove an attached thermocouple mini plug from the calibrator before you open the battery door.
  • Do not operate the calibrator if it is damaged.
  • Do not operate the calibrator around explosive gas, vapor, or dust.
  • Warning when servicing the calibrator, use only specified replacement parts.