Below are general answers on how to operate, maintain, and calibrate a hydrogen bromide gas detector from the list of GAO Tek’s hydrogen bromide gas detectors. To facilitate our customers to a selection of our products, we have further classified our hydrogen bromide gas detectors by their features: alarm-enabled, data logging , explosion-proof, handheld, high precision, outdoor, and wireless.
We have products in stock and can ship overnight to most places in the U.S. and Canada.
If you have any questions about our products or want to place an order, our technical experts can help you. Please fill out this form or email us.
Â
Operating Hydrogen Bromide Gas Detector:
Power On:
- Turn on GAO Tek detector and allow it to go through its startup sequence. This typically involves a self-test to ensure all systems are functioning correctly.
Zero Calibration:
- Ensure the detector is in clean air and perform a zero calibration if required. This sets the baseline for clean air with no HBr present.
Functional Check:
- Conduct a bump test using a known concentration of HBr gas to ensure the detector responds correctly.
Regular Monitoring:
- Use the detector to monitor HBr levels. This may involve carrying it on your person in a portable format or installing it in a fixed location for area monitoring.
Â
Maintaining a Hydrogen Bromide Gas Detector:
Regular Inspection:
- Check the physical condition of the detector regularly for any signs of damage or wear.
Sensor Check:
- Inspect the sensor and replace it if it is expired, damaged, or showing signs of drift.
Battery Maintenance:
- Regularly check and charge or replace batteries as needed.
Cleaning:
- Keep the detector clean, particularly the sensor area, to avoid false readings or damage.
Record Keeping:
- Maintain logs of inspections, maintenance activities, and any incidents of exposure.
Â
Calibrating a Hydrogen Bromide Gas Detector:
Frequency of Calibration:
- Follow GAO Tek’s recommendations for calibration frequency. This might be before each use, daily, weekly, or monthly.
Zero Calibration:
- In clean air, adjust the detector so that it reads zero in the absence of HBr.
Span Calibration:
- Expose the detector to a known concentration of HBr gas. This should be done using a calibration gas cylinder with a concentration within the range of the detector’s sensitivity.
Adjustment:
- Adjust the detector’s response to match the known concentration of the calibration gas.
Verification:
- After calibration, perform another bump test to verify accuracy.
Training:
- Ensure all users are adequately trained in the use of the HBr detector.
Safety Gear:
- Use appropriate personal protective equipment (PPE) when handling HBr gas or calibration gas.
Ventilation:
- Ensure adequate ventilation when calibrating or bump testing the detector.
Documentation:
- Keep records of all calibrations and maintenance activities.