Description
Features
- Real-Time Reporting Capability
- Accurate Fault Detection
- Versatile Testing Methods
- Durable And Lightweight
Technical Specifications
Operating System | Windows, touch operation mode, wireless expert guidance, scientific cable management, real-time report generation |
System Functions | Fault distance measurement, fault point location, propagation speed test, cable path search, buried depth detection |
Test Methods | Low-voltage pulse, flashover, audio, acousto-magnetic synchronization, valley, peak, electromagnetic induction methods |
Display Control | 12-inch industrial-grade control, built-in 12 V / 10 Ah DC power for 10 hours, single-chip microcomputer for other control |
Test Range | Distance: 37.28 mi (60 km), Depth: 6.56 ft to 16.4 ft (2 m to 5 m) |
Measurement Accuracy | Rough error: ±32.8 ft (10 m) or 1%, Fine error: ±0.66 ft (0.2 m) |
Sampling Frequency | 100 MHz, minimum resolution 1.64 ft (0.5 m) |
Sampling Method | Fully automatic continuous sampling, no missed discharge waveforms |
Low Voltage Pulse | Width: 0.1 μS and 2 μS, Amplitude: 100 Vpp |
Output Power | Path power: 100 W, Impact power: 0 W to 200 W |
Impact High Voltage | 0 V to 8 k V, 0 to 16 k V, 0 to 32 k V (optional) |
Short Circuit Current | 0 mA to 320 mA |
Burn Through Power | 0 J to 2450 J |
Dimensions | 16.93 in x 14.17 in x 9.06 in (43 cm x 36 cm x 23 cm) |
Weight | 17.6 lb (8 kg) |