Below are general answers on how to operate, maintain, and calibrate a chemical and water viscometer from the list of GAO Tek’s chemical and water viscometer to facilitate our customers to a selection of our products, we have further classified our chemical and water viscometers by their features: benchtop, brookfield, data logging, industrial, laboratory, paint, rotational, LCD-display and wide measurement range.

We have products in stock and can ship overnight to most places in the U.S. and Canada.

If you have any questions about our products or want to place an order, our technical experts can help you. Please fill out this form or email us.

 

Operating a Chemical and Water Viscometer:

Setup:

  • Place the viscometer on a stable surface.
  • Ensure that our viscometer is clean and free from any residues from previous use.

Sample Preparation:

  • Prepare the sample according to GAO Tek’s viscometer specifications.
  • Ensure the sample is at the desired temperature for viscosity measurement.

Temperature Control:

  • Some of our viscometers require temperature control. Set the instrument to the desired temperature or use a separate temperature bath for the sample.

Instrument Calibration:

  • Calibrate our viscometer using standard reference fluids of known viscosity. This is essential for ensuring accurate measurements.

Sample Loading:

  • Depending on the type of viscometer, load the sample into the appropriate chamber or cup.
  • Follow the GAO Tek’s guidelines for the correct sample volume.

Measurement:

  • Initiate the viscosity measurement according to GAO Tek’s instructions.
  • Record the viscosity reading provided by the viscometer.

 

Maintaining a Chemical and Water Viscometer:

Cleaning:

  • After each use, clean the viscometer thoroughly to prevent contamination between different samples.
  • Use appropriate cleaning solutions recommended by GAO Tek.

Regular Inspection:

  • Inspect the instrument for any signs of wear, damage, or malfunctions.
  • Check for any debris or residues that may affect accuracy.

Lubrication (if applicable):

  • Some viscometers may require lubrication of moving parts. Follow the GAO Tek’s recommendations for lubrication intervals and procedures.

Seal Inspection:

  • If the viscometer uses seals or gaskets, inspect them regularly for wear or damage.
  • Replace seals as needed to maintain the integrity of the instrument.

Sample Cup/Chamber Maintenance:

  • If the instrument uses disposable sample cups, replace them as recommended by GAO Tek.
  • Clean reusable sample chambers thoroughly to avoid cross-contamination.

 

Calibrating a Chemical and Water Viscometer:

Zero Calibration:

  • Adjust the instrument to read zero viscosity with the solvent or reference fluid.

Span Calibration:

  • Adjust the instrument to the viscosity of a standard fluid with a known viscosity value.

Verification:

  • Confirm that the instrument readings match the known viscosity values of the calibration standards.

Calibration Frequency:

  • Calibrate the viscometer regularly, as specified by GAO Tek or based on the frequency of use.

 

General Tips:

  • Always use the detector in accordance with GAO Tek’s guidelines.
  • Be aware of the lifespan of sensors, as they will need replacing after a certain period or number of exposures.
  • Ensure all personnel using the detector are adequately trained in its operation and interpretation of results.