 GAOTek multiparameter water sensors are a family of high-performance sensors designed to measure multiple water quality parameters in a single unit. These sensors are ideal for a wide range of applications, including water and wastewater treatment, environmental monitoring, and industrial process control.
Â
Features
- 3-inch colour high contrast LCD touchscreen
- Intelligent operation system
- Multi-reading feature
- Automatic/Manual temperature compensation
- Auto-hold feature
- Data Storage 1000 sets for each parameter (GLP-compliant)
- Data analysis feature
Technical Specifications
Parameters | PH / EC / ISE / Temp. (mV /ORP/ pX/ Resistivity / TDS / Sal.) | |
pH |
Range | -2.000 pH to 20.000 pH |
Resolution | 0.1 pH, 0.01 pH, 0.001pH | |
Accuracy | -0.002 pH to 0.002 pH | |
Calibration Points | Up to 8 | |
Standard Customization | Yes | |
Calibration Reminder | Yes | |
Standard Recognition | USA, NIST, MERK, JIS, GB and DIN buffers | |
Slope Limit | Yes | |
mV/ORP |
Range | -2000.00 mV to 2000.00 mV |
Resolution | 0.1 mV, 0.01 mV | |
Accuracy | ± 0.1 mV or ± 0.03% | |
EH ORP Mode | Yes | |
ORP Calibration Points | 1 custom point (relative mV) | |
pX |
Range | -2.000 pX to 20.000 pX |
Resolution | 0.1 pX, 0.01 pX, 0.001 pX | |
Accuracy | -0.002 pX to 0.002 pX | |
Calibration Points | Up to 6 | |
ISE |
Range | 1E-9 to 9.999 E9 |
Units | mol/L, mmol/L, g/L, mg/L, μ g/L | |
Resolution | Up to 4 significant digits | |
Accuracy | -0.3% to +0.3% | |
Calibration Points | Up to 8 | |
Conductivity |
Range | 0.000 μ S/cm to 3000 mS/cm |
Resolution | 0.001 μ S/cm minimum, various with range selection | |
Accuracy | – 0.5% FS to 0.5% FS | |
Reference Temperature | 41 ºF, 50 ºF, 59 ºF, 64.4 ºF, 68 ºF, and 77 ºF (5 ºC, 10 ºC, 15 ºC, 18 ºC, 20 ºC, 25 ºC) | |
Calibration Points | Up to 5 | |
Calibration Reminder | Yes | |
Standard Recognition | 0.00 in, 0.00 in, 0.02 in, 0.06 in, 0.51 in (10 μ S/cm, 84 μ S/cm, 500 μ S/cm, 1413 μ S/cm, 12.88mS/cm) | |
Resistivity |
Range | 1.96 Ω · in to 39.37 Ω · in (5.00 Ω ·cm to 100.00 M Ω ·cm) |
Resolution | 0.003 Ω · in (0.01 Ω ·cm) minimum | |
Accuracy | – 0.5% F. S to 0.5 F. S | |
TDS |
Range | 0 lb to 2.20 lb (0.000 mg/ to 1000 g/L) |
Resolution | 2.20 lb (0.001 mg/L) minimum, changed with range | |
Accuracy | -0.5% to 0.5% | |
Salinity |
Range | 0.00% to 8.00% |
Resolution | 0.01% | |
Accuracy | -0.1% to +0.1 | |
Temperature |
Range | 14 ºF to 275 ºF (-10 ºC to 135 ºC) |
Unit | ºC, ºF | |
Resolution | 0.1 | |
Relative Accuracy | -0.1 to +0.1 | |
Measurement |
Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
Reading Prompts | Reading, Stable, Locked | |
Temp. Compensation | ATC, MTC | |
Data management |
Data Storage | 1000 Groups |
GLP Features | Yes | |
Inputs |
pH Electrode | BNC (Q9) |
DO with Temp. Probe | 4-pin aviation connector | |
Conductivity with Temp. Probe | 5-pin aviation connector | |
Outputs |
USB | USB 2.0 flash memory device, PC, scanner |
Bluetooth | Printer | |
Display options |
Backlight | Yes |
Auto Shutdown | 300 s, 600 s, 1200 s, 1800 s, 3600 s. | |
IP Rating | IP 65 | |
Date and Time | Yes | |
General |
Power | Rechargeable Lithium battery, AC Adapter, 100 V to 240 V AC input, DC 5 V output |
Dimensions | 3.5 in x 10.03 in x 1.57 in (90 mm x 255 mm x 40 mm) | |
Weight | 500 g (1.1 lb) |