Description
Features
- Unmatched Fastest performances
- 100% automated bidirectional test at two wavelengths under 5 seconds
- 100% automated fiber inspection
- One-step process with pass or fail analysis at both fiber ends
- Onboard assistant and diagnosis to eliminate reference errors
- Bright, 7 in (17.78 cm) high-resolution touchscreen display
- The biggest in the market
- Optical return loss (ORL) meter
- Market-leading onboard PDF reporting solution
- Essential PC‑based post‑processing included for all users
- Best-in-class single mode distance range of 124.2 mi (200 km)
- EXFO Connect-ready for cloud-based test assets management
- Wi-Fi and Bluetooth connectivity (optional)
Technical Specifications
Detector type | In GaAs |
Wavelength | 1310 nm or 1550 nm |
Loss range (dB) | Multimode: 20 dB, Single mode simplex: 45 dB, Single mode duplex: 50 dB |
ORL measurement range (dB) | 50 dB |
Power supply | AC or DC adapter, input 100 VAC to 240 VAC, 50 Hz to 60 Hz |
Battery | Rechargeable lithium-polymer battery12 hrs of operation |
Interfaces | Two USB 2.0 ports RJ45 LAN 10 or 100 M bit or s, Optional Wi-Fi or Bluetooth |
ORL range (APC or UPC link) (dB) | 65 dB or 55 dB |
ORL uncertainty (dB) | ±0.5 dB |
Resolution (dB) | 0.01 dB |
ORL measurement uncertainty (dB) | ±1 dB |
ORL measurement range (dB) | 50 dB |
Length measurement uncertainty | Duplex: 19.68 in ± 1.64 ft (0.5 m +0.5% x length)Simplex: 3.2 ft ± 3.2 ft (1 m +0.5% x length) |
Length measurement range (km) | Multimode: 12.4 mi (20 km)Single mode: 124.2 mi (200 km) |
Loss range (dB) | Multimode: 20 dBSingle mode simplex: 45 dB
Single mode duplex: 50 dB |
Launch condition | Encircled Flux (EF) compliancy guaranteed at 0.001 in or 0.004 in (50 µm or 125 µm) multimode source port. Within TIA-526-14-B, ISO or IEC 14763-3 and IEC 61280-4-1 EF template limits at the end of an EXFO reference grade‑ 0.001 in or 0.004 in (50 µm or 125 μm) test cord |
Wavelengths (nm) | Multimode (LED): 850 nm ±20 nm, 1300 nm ±20 nmSingle mode (laser): 1310 nm ±20 nm, 1490 nm ±10 nm, 1490 nm ±10 nm, 1625 nm ±10nm. |
Testing speed | Fastest Simplex: 3 seconds (two wavelengths, bidirectional, automated, IL + fiber length)Fastest Simplex: 6 seconds (three wavelengths, bidirectional, automated, IL + ORL + fiber length) |
Spectral width (FWHM) (nm) | 850 nm: 30 nm to 60 nm1300 nm: 100 nm to 150 nm |
Output power stability (dB) | ±0.05 dB over 8 hrs |
Output power (dBm) | Multimode (850 nm or 1300 nm): –25 dBmSM1 (1310 nm or 1550 nm): 2.5 dBm
SM3 (1310 nm or 1550 nm or 1625 nm): 1 dBm or –1 dBm or –5 dBm SM4 (1310 nm or 1490 nm or 1550 nm): 1 dBm or –5 dBm or –1 dBm |
Tone detection (Hz) | 270 Hz or 330 Hz or 1000 Hz or 2000 Hz |
Wavelengths range (nm) | 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1577 nm, 1625 nm, 1650 nm |
Measurement range (dBm) | 25 dBm to —50 dBm |
Uncertainty | ±(5% + 10 nW) |
Detector type | Gex |
Size (H x W x D) | 6.5 in x 7.87 in x 2.66 in (166 mm x 200 mm x 68 mm) |
Weight (with battery) | 3.3 lb (1.5 kg) |