Description
Features
- Using imported high precision sensor
- 100,000 sets of data can be stored, storage interval available set, minimum 5S,
- LCD display, can display the type of gas, the gas unit, gas concentration values, measured maximum, local time, ambient temperature
- English operation interface
- Gas concentration unit PPM, mg per m3 can quickly switch display
- Built-in micro sampling pump, the pump suction size ten stalls adjustable
- CE certification, Exia II CT4, IP66
- Monitoring of the environment, or the concentration of chlorine CL2 in a confined space and give an alarm
- With self-check function, zero calibration function, so that gas monitoring more accurate and reliable
- One key to restore the factory settings, can be removed from misuse problems
- With temperature and pressure compensation, to achieve the perfect, different temperature and pressure environment, the gas concentration compensation
- Two sound and light alarm, alarm point can be set
- Large-capacity lithium polymer rechargeable battery
- Pump suction sampling, adjustable suction pump
- Shell with high-strength special engineering plastics, non-slip, waterproof, dustproof, explosion
- Exquisite upscale aluminum suitcase
Â
Technical Specifications
Data logger | 100,000 sets of data can be stored, storage interval available set, minimum 5 S, can be browse |
Measure Range | 0 ppm to 10 ppm, 20 ppm, 50 ppm, 100 ppm, 200 ppm |
Resolution | 0.01 ppm,0.1 ppm |
Precision | 2% FS |
Response Time | ≤ 10 S |
Repeatability | ≤ ± 1 % |
Zero shift | ≤ ± 1 % (F.S or Year) |
Explosion-Proof | Exia II CT4 |
Recovery Time | ≤ 10 S |
Linearity error | ≤ ± 1 % |
Display | LCD |
Gas unit | Multiple gas unit |
Humidity | 0 % RH to 95 % RH |
Degree of protection | IP66 |
Operating time | 100 hours (off pump) |
Temperature | -40 ºF to 158 ºF (-40 ºC to 70 ºC) |