Description
Overview
This RFID temperature tag provides highly accurate, real-time data collection without human intervention in wireless applications such as identification, tracking, cold chain, localization of high value assets and temperature monitoring.
This temperature tag transmits and receives data at distances of up to 250 m (800 feet). It can also be easily configured to beacon data at a range of up to 500m (1600 ft). The long range tag contains an internal temperature monitoring sensor in order to measure and log the temperature of goods in definable intervals. It is also available with external sensors. Using an integrated LED, the sensor provides visual recognition. This tag is able to store user and process information as well as temperature data to provide real-time tracking.
Key Features
- Beacon communication mode
- Response communication mode
- Spot location for gate applications
- 10,000 Bytes memory
- 2000-sensor simultaneous identification
- Temperature logging
- Non-line-of-sight data transmission
- LED
- Localization of high value assets
Applications
- Identification
- Cold chain
- Localization of high value assets
- Temperature monitoring
Technical Specifications
Communication Broadcast | |
Operation Mode | Transmits Sensor ID and user data in pre-defined interval |
Read Range | up to 500m (1600ft)* |
Compatibility | 227002, 227003, 227004 |
Operating Frequency | 868 MHz (EU) or 920 MHz (NA |
Transmit Power | <1mW |
Communication Response | |
Operation Mode | Bi-directional communication (reading log, blink LED, write/read data) |
Read Range | up to 250m (800ft)* |
Compatibility | 227002, 227003, 227004 |
Operating Frequency | 868 MHz (EU) or 920 MHz (NA) |
Transmit Power | <1mW |
Communication Marker | |
Operation Mode | Receives Marker ID and transmits marker information several times via Broadcast 350 telegrams |
Read Range | up to 5 m (16ft)* |
Compatibility | 491013,491014 |
Operating Frequency | 125 kHz |
Temperature Sensor | |
Number of logging samples | 10.000 |
Logging Interval | user definable in intervals from 1 to 255 min |
Measuring Interval | user definable in intervals from 0 seconds to 255 min |
Metering Range | -40°C to +85°C (-40°F to +176°F) with integrated sensor -80°C to +100°C (-112°F to +212°F) with external sensor |
Resolution | 0.1 °C (0.2 °F) |
Accuracy | +- 0.5 °C (1 °F) from -20 °C up to +50 °C (68° F up to 122°F) +- 1.0 °C (2 °F) in the remaining temperature range |
Environmental Conditions | |
Operating Temperature | –40 °C to +85 °C (–40 °F to +185 °F) |
Shock | Multiple drops to concrete from 1m (3ft), 3 times DIN IEC 68-2-27 |
Humidity | 10% to 95% relative humidity at30°C (86°F) |
Vibrations | 3G, 20 sine wave cycles, 5 to 150 Hz, DIN IEC 68-2-6 5G, noise 5 to 1.000 Hz, 30 minutes, DIN IEC 68-2-64 |
Data | |
Data Retention | > 10 years without power |
Write Cycles | 100,000 writes |
Memory Size | 10,000 Bytes user definable |
Identification Code | 48 bit fixed ID |
Configuration | |
Device | 227002, 227003, 227004 |
Ping Rate | Configurable from 0.5 to 300 seconds insteps of 0.5 seconds |
Number of Bursts | Configurable from 0 to 15 |
Broadcast User Data | Up to 50 Bytes |
Electrical | |
Power Source | Lithium Battery (non-replaceable) |
Battery Monitoring | Yes |
Standard/Certification | |
Europe | CE (EN 300 220-1, -3; EN 301 489-1,-3; EN 60950) |
North America | FCC Part 15 (US); Industry Canada |
Physical | |
Dimensions | 131 × 28 × 21 mm (5.2 × 1.1× 0.85 inches) |
Enclosure | Plastic (Qinnacryl) |
Weight | 50 g (1.75 ounces) |
Enclosure rating | IP 65 |