Overview
GAOTek AC or DC Clamp Meter measures very low and very high resistance with this True RMS AC or DC clamp meter. It features a VFD low-pass filter, which provides accurate motor drive measurements and is ideal for troubleshooting non-linear signals. Additionally, this instrument is compatible with the Fluke Connect application and iFlex flexible current probe.
Features
- Read measurements on your phone at a safe distance
- Wearing less PPE while your meter takes all the risks
- Record results directly to your phone and the Cloud
- Capture intermittent faults and multitask with Fluke 375 FC’s logging
- Create and share reports from the field via email
- Converse in real-time with Share Liveâ„¢ video calls
- Compatible with iFlex flexible current probe
- Use to expand the measurement range to 2500 A ac
- Provides access to large conductors in tight spaces
- Compatible with TPAK magnetic hanging strap
- Integrated VFD low pass filter for accurate motor drive measurements
Technical Specification
Range | 600 A |
Resolution | 0.1 A |
Accuracy | 2 % ± 5 digits (10 to 100 Hz) 2.5 % ± 5 digits (100 to 500 Hz) |
Crest Factor (50 or 60 Hz) | 3 at 500 A 2.5 at 600 A Add 2% for C.F. > 2 |
AC Current via Flexible Current Probe | |
Range | 2500 A |
Resolution | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
Accuracy | 3 % ±5 digits (5 to 500 Hz) |
Crest Factor (50 or 60 Hz) | 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. > 2 |
DC Current | |
Range | 600.0 A |
Resolution | 0.1 A |
Accuracy | 2 % ± 5 digits |
AC Voltage | |
Range | 1000 V |
Resolution | 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
Accuracy | 1.5 % ± 5 digits (20 Hz to 500 Hz) |
DC Voltage | |
Range | 1000 V |
Resolution | 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
Accuracy | 1 % ± 5 digits |
mV DC | |
Range | 500.0 mV |
Resolution | 0.1 mV |
Accuracy | 1 % ± 5 digits |
Frequency via Jaw | |
Range | 5.0 to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % ± 5 digits |
Trigger Level | 5 to 10 Hz, ≥ 10 A 10 to 100 Hz, ≥ 5 A |
Frequency via Flexible Current Probe | |
Range | 5.0 to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % ± 5 digits |
Trigger Level | 5 to 20 Hz, ≥ 25 A 20 to 100 Hz, ≥ 20 A 100 to 500 Hz, ≥ 25 A |
Resistance | |
Range | 60 kΩ |
Resolution | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
Accuracy | 1 % ± 5 digits |
Capacitance | |
Range | 1000 µF |
Resolution | 0.1 µF (≤ 100 µF) 1 µF (≤ 1000 µF) |
Accuracy | 1 % ± 4 digits |
General Specifications | |
Maximum Voltage Between Any Terminal and Earth Ground | 1000 V |
Batteries | 2 x AA alkaline, NEDA 15A, IEC LR6 |
Operating Temperature | 14 °F to 122 °F (-10 °C to 50 °C) |
Storage Temperature | 40 °F to 140 °F (-40 °C to 60 °C) |
Operating Humidity – Non-Condensing (< 50 °F (10 °C)) | ≤ 90 % RH at 50 °F to 86 °F (10 °C to 30 °C) ≤ 75 % RH at 86 °F to 104 °F (30 °C to 40 °C)] |
Operating Altitude | 1.86 mi (3000 m) |
Storage Altitude | 24.46 mi (12,000 m) |
Jaw Opening | 0.02 mi (34 mm) |
Flexible Current Probe Diameter | 24.60 ft (7.5 mm) |
Flexible Current Probe Cable Length (Head to Electronics Connector) | 5.90 ft (1.8 m) |
Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V or CAT IV 600 V |
IP Rating | IEC 60529: IP30, non-operating |
Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE |
Dimensions | 9.8 in x 3.3 in x 1.8 in (249 mm x 85 mm x 45 mm) |
Weight | 0.87 lb (395 g) |