Description
Overview
GAOTek ammonia gas analyzer is possible for the real-time monitoring via the wired or remote wireless transmission, and network transmission; three-wire system 4 to 20 mA standard signal and standard bus RS485 (Modbus-RTU) simultaneous output; it is compatible with secondary instrument, data acquisition module, PLC, DCS system, and it is possible to drive the related equipment. Data recovery function; in case of mis-operation, it is possible to select partial or full recovery. Multiple alarm modes, and multi-directional and three-dimensional indication alarm states. It includes 2 sets of relay switch output, sound and light alarm (optional configuration). Alarm types include concentration alarm, and failure alarm.
Features
- Fixed Gas Detector Online Toxic and Harmful
- Lightning protection, Overvoltage protection
- Safe and Reliable, Anti-Reverse connection
- Sound-light alarm(optional), Ant-surge, Anti-static
- Detection gas more than 500 types
- Diffusion Type (Optional pipe type, flow type, pump type)
- Detection sensor: Breathable dustproof net
- Effective protection extended sensor life
- Explosion-proof enclosure: Integrated molding
- Wear-resistant and durable
- Multi-protection design: Die cast aluminum shell
- IP65 protection grade, Dustproof, Waterproof
- Explosion-proof grade Exd IICT6
- Advantages: Real-time Detect, Mult signal output
- Endurance and multi-protection
Technical Specifications
Detection Range | 0 to 10 ppm 0 to 20 ppm 0 to 50 ppm 0 to 100 ppm Other ranges can be customized |
Resolution | 0.01 ppm or 0.001 ppm (0 to 10 ppm); 0.01 ppm (0 to 100 ppm), Other ranges can be customized |
Detection Principle | Electrochemical, infrared, thermal conductivity, PID photoionization, and so on. Depending on the type of gas, range, field environment and user demand, Sensor can be customized |
Sensor Service Life | Electrochemical principle: 2 to 3 years; Infrared principle: 5 to 10 years; Thermal conductivity: 5 years |
Allowable Error | ≤ ± 3% F.S (other or higher precision levels can be customized) |
Linearity | ≤ ± 2% |
Repeatability | ≤ ± 2% |
Uncertainty | ≤ ± 2% |
Response Time | T90 ≤ 30 seconds |
Recovery Time | ≤30 seconds |
Working Voltage | 12 to 30 VDC direct current the standard power supply for a single equipment is 24 V, DC stabilized voltage switching power supply of 1 A or greater than 1 A |
Power Supply Reference | 24 V, 2.1 A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared gas detector. |
Working Method | Fixed type installation, online detection, diffusion type measurement |
Protection Level | IP65 |
Explosion-proof Mark | Exdâ…¡CT6, certificate number: CNEx15.1283 |
Working Environment | Temperature: -40 °F to 158 °F (-40 ℃ to 70 ℃), humidity: ≤ 10 to 95% RH (regular) |
Exterior Dimensions | 9.1 in x 8.0 in x 2.5 in (233 mm x 205 mm x 65 mm) (L × H × W) |
Weight | 2.2 lb. (1.0 Kg) |