Description
Key Features
- For measurement of high concentration gas up to 100 vol%
- Suitable for inspecting the amount of gas remaining in tanks
- New digital display with a simulated analog scale
- Extended battery life of up to 30 hours
Technical Specifications
Gas Detected | Methane, Propane, Argon, Carbon dioxide, etc. (specify gas detected) |
Detection Principle | Thermal conductivity |
Sampling Method | Extractive |
Detection Range | 0% to 100% |
Indication Accuracy (Under identical conditions) |
H range: ±5% L range: ±10% |
Alarm Set Value | 50% |
Display | LCD digital (with backlight) Digital display: 0% to 100% Digital bar display: Auto range changeover 0% to 10% or 0% to 30% (L range) 0% to 100% (H range) |
Alarm Indication | Gas alarm: Intermittent buzzer, red lamp flashing Error alarm: Buzzer, Red lamp flashing, LCD display |
Explosion-Proof Structure | Exdib IIC T 3 (TIIS) Ex II 2 G Exdib IIB T 4 Gb (ATEX) Exdib IIB T 4 Gb (IECEX) Class I, Zone 1, AEX d ib IIB 4 Hazardous Locations. (UL) |
Operation Temperature | 32 °F to 104 °F (0 °C to 40 °C) |
Power Source | 4 x AA alkaline dry battery |
Battery Life | Up to 30 hours |
Dimensions | 3.2 in x 6.3 in x 1.4 in (82 mm x 162 mm x 36 mm) |
Weight | 0.9 lb (450 g) |