Description
Features
- Automated gain, Peak Hold and Peak Memory
- Automated display precise flaw location (Depth d, level p, distance s, amplitude, sz dB)
- Ten independence setups, any criterion can be input freely, we can work in the scene without test block
- Big memory of 300 A graph and 30000 thickness value
- Gate and DAC alarm; Acoustic-Optical alarm
- RS232 port, communication with pc is easy
- The embedded software can be online updated
- Li battery, continue working time up to 7 hours
- Other assistant function
- Display freeze
- Automated echo degree
- Angles and K-value
- Lock and unlock function of system parameters
- Dormancy and screen savers
- Electronic clock calendar
- Two gates setting and alarm indication
- High-speed capture and very low noise
- DAC, AVG; Solid metal housing (IP65)
- Provides high contrast viewing of the waveform from bright, direct sunlight to complete darkness and easy to read from all angles
- Powerful pc software and reports can be exported to excel
Technical Specifications
Range Of Scanning (mm) | Range of scanning (mm): 0.1 in to 2362.20 in (2.5 mm to 60000 mm) (Steel Longitudinal wave) Steps: 2.5, 5, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 250, 300, 350, 400, 50, 500, 600, 700, 800, 900, 1000, 2000, 3000, 4000, 5000, 6000 Adjusting step: 0.004 in (0.1 mm) (0.1 in to 3.93 in (2.5 mm to 99.9 mm)), 0.04 in (1 mm) (3.93 in to 393.70 in (100 mm to 10000 mm)) |
D-delay (ms) | D-delay (ms): -20 to +3400 Steps: -20, -10,0.0, 10, 20, 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3400. Adjusting steps: 0.1(-20 ms to 999.9 ms), 1(1000 ms to 3400 ms) |
P-delay (ms) | P-delay:0.0 to 99.99 Adjusting steps: 0.01 |
MTLVEL(m/s) | MTLVEL:1000 to 9999 7 fixed levels: 2260, 2730, 3080, 3230, 4700, 5920, 6300 Adjusting steps:1 |
Working Mode | Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe) |
Frequency Range (MHz) | 0.4 to 20 |
Gain Adjustment (dB) | 0 to 110 Adjusting step: 0.0,0.2,0.5,1,2,6,12 |
Reject | 0% to 80% of screen height, step: 1% |
Vertical Linear Error | Vertical linear error is not more than 3% |
Horizontal Linear Error | Not more than 0.2% in the scanning range |
Sensitivity Leavings | ≥62 dB |
Dynamic Range | ≥32 dB |
Alarm | Three modes, i.e., forbidden wave, loss wave and auto |
Monitoring Door | 2, expressed by bold transverse line, whose start, width and height are adjustable. Adjusting range of start (mm): horizontal pixel 0 in to 8.19 in (0 mm to 208 mm), the displayed value is relative with the scanning range. Step: value in mm corresponding to a pixel (relative with the scanning range) Adjusting range of width (mm): horizontal pixel 0.16 in to 8.35 in (4 mm to 212 mm), the displayed value is relative with the scanning range. Step: value in mm corresponding to a pixel (relative with the scanning range) Adjusting range of height: 2% to 90% of vertical graduation Step graduation: 1% |
Display | Display: high-brightness lattice |
A-Scan Display Area | Full screen or local A-Scan display freezing and de-freezing A-Scan filling |
Data Save | 300 A-Scan images (including setting of instrument) 30000 values of thickness (300 sets) |
Standard Communication Interface With PC | RS 232 |
Measuring Unit | Mm/in |
Battery | Li battery 4 × 3.6 V 4800 mAh |
Power Adaptor | Input 100 V to 240 V/50 Hz to 60 Hz Output 9 V to 12 V DC/1.5 A |
Working Humidity | 20% to 90% |
Port Type | BNC |
Working Temperature | -4 °F to 158 °F (-20 ℃ to 70 ℃) |
Dimension (mm) | 9.45 in × 7.09 in × 1.97 in (240 mm × 180 mm × 50 mm) |
Weight (kg) | 3.97 lbs. (1.8 kg) |