Rate Input Voltage |
48 VDC |
Range Input Voltage |
48 VDC ± 15% |
Output voltage |
300 VDC ± 2% |
Output current |
5 A |
Loading rate |
It is recommended that the general load continuous work control at about 80%, power motor class inductive, capacitive, amplifier, radio and other loads with a load of about 40-50% is better |
Working time |
24 × 7 (80% Load) |
Overload and current |
110% to 150% |
Low voltage protection |
Start up below 18% of rated input voltage |
Empty Load Loss |
< 3 W |
Empty current |
< 0.2 A |
Overload protection |
105% to 135% |
Start-up time |
1 S to 2 S |
Seismic resistance |
10 Hz to 500 Hz,2G 10 sec, 1 cycle, total 60 min, each axis |
Pressure resistance |
Between input and output: 1.5 KVAC, input and enclosure: 1.5 KVAC output and enclosure: 0.5 KVAC |
Isolation situation |
Input and output isolation status |
Isolation resistors |
Between input and output, input to enclosure, output to enclosure: 500 VDC, 100 M Ohms |
Working temperature, humidity |
-86 °F to +149 °F (-30 ℃ to +65 ℃, 20% to 90% RH) |
Storage temperature, humidity |
-104 °F to +185 °F (-40 ℃ to +85 ℃, 10% to 95% RH) |
Housing material |
Aluminum |
Dimension |
17.32 in × 11.81 in × 4.33 in (440 mm × 300 mm × 110 mm) |
Net weight, Gross weight |
11.02 lb (5 kg) |