Description
Overview
GAOTek desktop USB digital storage oscilloscopes are super-economical types of digital storage oscilloscopes. The 2-channel oscilloscopes have a bandwidth of 200 MHz. They have ultra-thin bodies and are designed with 7 in (17.78 cm) high-resolution LCDs. They support SCPI and LabVIEW. They are used for electronic circuit debugging, circuit testing, design and manufacture, education and training, and automobile maintenance and testing.
Features
- single channel 500 MS/s
- double channel 1GS/s 5 ns/div to 1000 s/div
- 1 GSa/s Real Time sample rate
- Large 7 in (17.78 cm) TFT color screen
- Record length up to 10 kHz
- 30 automatic measurement values
- With 16 waveform parameter measurements
- Plug and play USB, can relate to computer communication
- system software upgrade with U disk
- Support the stored waveform and the current waveform
- Ultra-thin body, portable
Technical Specifications
Sample Rate (real Time) |
Single channel;500 MS/s double channel:1 GS/s
500 MS/s 1 GS/s |
Input Coupling | DC, AC, Ground |
Input Impedance | 1 MΩ±2%, in parallel with 20 pF±5 pF |
Input Coupling | 1X,10X,100X,1000X |
Max. Input Voltage | 400 V (DC + AC, PK – PK) |
Channel–Channel Isolation | 50 Hz: 100: 1 10 MHz: 40: 1 |
Time Delay Between Channel(typical) | 150 ps |
Bandwidth Limit | 20 MHz, full bandwidth |
Sampling Rate Range | 0.5 S/s to 200 MS/s
0.5 S/s to 500 MS/s 0.5 S/s to 1 GS/s |
Interpolation | (Sin x)/x |
Max Record Length | 10 K |
Scanning Speed (S/Div) | 5 ns/div-1000 s/div, step by 1-2-5 ≤3 .5 ns
2 ns/div to 1000 s/div, |
Sampling Rate or Relay Time Accuracy | ±100 ppm |
Interval (△t) Accuracy (DC-100 MHz) |
Single: ± (1 interval time+100 ppm×reading+0.6 ns); Average>16: ± (1 interval time +100 ppm×reading+0.4 ns) |
Vertical Resolution (A or D) | 8 bits (2 channels simultaneously) |
Sensitivity | 5 mV/div to 5 V/div |
Displacement | ±2 V (5 mV/div to 100 mV/div) ±50 V (200 mV/div to 5 V/div) |
Analog Bandwidth | 200 MHz
50 MHz 100 MHz |
Single Bandwidth | Full bandwidth |
Low Frequency | ≥10 Hz (at input, AC coupling, -3 dB) |
Rise Time (At Input, Typical) | ≤ 17.5 ns
≤ 7.0 ns ≤ 3.5 ns |
DC Gain Accuracy | ± 3 % |
DC Accuracy (Average) | Delta Volts between any two averages of ≥16 waveforms acquired with the same scope setup and ambient conditions (△V): ±(3% reading + 0.05 div) |
Cursor | △V, △T, △T&△V between cursors, auto cursor |
Automatic | Period, Frequency, Mean, PK-PK, RMS, Max, Min, Top, Base, Amplitude, Overshoot, Preshoot, Rise Time, Fall Time, +Pulse Width, -Pulse Width, +Duty Cycle, -Duty Cycle, Delay A→B, Delay A→B, Cycle RMS, Cursor RMS, Screen Duty, Phase, +Pulse Count, -Pulse Count, Rise Edge Count, Fall Edge Count, Area, and Cycle Area. |
Waveform Math | +, -, *, /, FFT |
Waveform Storage | 16 waveforms |
Trigger Level Range | ±5 div from the screen center |
Trigger Level Accuracy (Typical) | ±0.3 div |
Trigger Displacement | According to Record length and time base |
Trigger Holdoff Range | 100 ns to 10 s |
50% Level Setting | Input signal frequency ≥ 50 Hz |