Description
Features
- Conductivity meter host
- Detection probe
- RS232 communication interface
- Detection probe interface
- Charger interface
- Lithium-ion battery charger
- RS232 communication cable
- Conductivity standard test block
- Lithium-ion rechargeable battery
- Temperature sensor
- Operation manual and CD
- Host bracket
- Portable protective case
Technical Specifications
Display Type | Digital Only |
Accuracy Class | ±1% 32 °F to 104 °F (0 °C to 40 °C), ±0.5% 68 °F (20 °C) |
Operating Temperature | 32 °F to 122 °F (0 °C to 50 °C) |
Type | Non-ferrous Metal Conductivity Tester |
Measurement Range | 0.51% IACS to 112% IACS, 0.3 MS/m to 65 MS/m, resistivity 0.01538 Ω·mm²/m to 3.33333 Ω·mm²/m |
Resolution | 0.01% IACS (for < 51% IACS) 0.1% IACS (for 51% IACS to 110% IACS range) |
Operating Frequency | 60 KHz Sine Wave |
Attachment | Probe, 3 Standard Blocks, Data Cable, CD, Charger |
Attachment 1 | Operation Manual, Temperature Sensor, Instrument Holder |
Power Supply | 3.7 V/2200 mA/h Lithium Ion Battery |
Working Frequency | 60 KHz Sine Wave |
Conductivity Measurement Range | 7.76% IACS to 112% IACS, 4.5 MS/m to 65 MS/m, or resistivity 0.01538 Ω·mm²/m to 0.22222 Ω·mm²/m 0.51% IACS to 112% IACS, 0.3 MS/m to 65 MS/m, or resistivity 0.01538 Ω·mm²/m to 3.33333 Ω·mm²/m |
Resolving Power | 0.01% IACS (less than 51% IACS) 0.1% IACS (51% IACS to 110% IACS range) |
Measurement Accuracy | ±1% of the Measured Value (at 32 °F to 104 °F (0 °C to 40 °C)), ±0.5% of the Measured Value |
Lift-off Effect | Probe Compensation |
Temperature Measurement | 32 °F to 122 °F (0 °C to +50 °C) (Accuracy up to 32.9 °F (0.5 °C)) |
Automatic Compensation Function | The conductivity measurement result is automatically corrected to the value of 68 °F (20 °C) |
Normal Working Environment | Temperature 32 °F to 122 °F (0 °C to +50 °C), Relative Humidity 0% to 95% |
Display | Large LCD with Backlight |
Power Supply (continued) | Provided with 3.7 V/2200 mA/h Lithium Ion Battery |
Probe | Type A and A1 machines are equipped with a probe with a diameter of 14 mm and a working frequency of 60 KHz. The probe can be replaced by itself |
Reading Memory | 500 Groups of Measurement Data Can Be Saved |
Instrument Housing | High Impact Resistance, Waterproof Engineering Plastic Shell |
PC Communication Mode | RS 232 Serial Port |
Enclosure | Two A1 Type Conductivity Standard Test Blocks and Three a Type Conductivity Standard Test Blocks are Randomly Assigned; More Standard Test Blocks Can Be Provided for Users to Choose |
Host Size (mm/inches) | 8.66 in x 3.74 in x 2.17 in (220 mm x 95 mm x 55 mm) |
Main Engine Weight | 1.1 lb (500 g) (Including Battery) |
Dimensions (mm/inches) | 8.66 in x 3.74 in x 2.1654 in (220 mm x 95 mm x 55 mm) |