GAOTek electrical tester measures voltage up to 1000 V AC through its open fork without any test lead contact to the live voltage. Additionally, this tool fits in your pocket and comes equipped with Field Sense technology, which detects an electrical field. It is the first-ever instrument of its kind. Thanks to Fluke’s unique Field Sense technology, the device can measure voltage up to 1000 V AC using only the meter’s open fork. You don’t need to open covers or remove wire nuts to take voltage readings on AC sources. The meter’s open fork jaw measures 0.7 in (17.8 mm) and is large enough to fit wires up to AWG 4/0. It can also measure current up to 200 An AC through its open fork while showing voltage and current readings on its backlit screen.Â
Features
- Field Sense for touchless AC voltage, current, and frequency measurement
- Simultaneous display of voltage and current for efficient troubleshooting
- 1 V to 1000 V AC or DC
- 0.1 A to 200 A AC
- Resistance 1 Ω to 100 kΩ
- Frequency measurement 45 Hz to 66 Hz
- Works with wires up to AWG 4/0 4.7 in (120 mm) with a 0.7 in (17.8 mm)Â
- The hold button temporarily freezes the reading for easy viewing
- Easy-to-read display with backlight
Technical Specification
Field Sense AC Voltage True RMS | |
Requires Test Leads | No |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ± (3 % + 3 counts) 45 Hz to 66 Hz |
Field Sense AC Current True RMS | |
Requires Test Leads | No |
Range | 200.0 A |
Resolution | 0.1 A |
Accuracy | ± (3 % + 3 counts) 45 Hz to 66 Hz |
Field Sense Frequency (Hz) | |
Requires Test Leads | No |
Range | 45 Hz to 66 Hz |
Resolution | 1 Hz |
Accuracy | ± (1 % + 2 counts) |
Volts AC True RMS | |
Requires Test Leads | Yes |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ± (1.5 % + 2 counts) 45 Hz to 66 Hz |
Volts DC | |
Requires Test Leads | Yes |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ± (1 % + 2 counts) |
Resistance | |
Requires Test Leads | Yes |
Range | 1000 V 2000 Ω 20 kΩ 100 kΩ |
Resolution | 1 V 1 Ω 0.01 kΩ 0.1 kΩ |
Accuracy | ± (1 % + 2 counts) |
Safety | |
Range | 1000 V CAT III 600 V CAT IV |
General Specifications | |
Calibration | One year calibration cycle |
Jaw Opening | 0.7 in (17.8 mm) |
Operating Temperature | 14 °F to 122 °F (-10 °C to 50 °C) |
Storage Temperature | -22 °F to 140 °F (-30 °C to 60 °C) |
Operating Altitude | 1.24 mi (2000 m) |
Storage Altitude | 6.21 mi (10000 m) |
Relative Humidity | 0 % to 90 %, 41 °F to 86 °F (5 °C to 30 °C) 0 % to 75 %, 86 °F to 104 °F (30 °C to 40 °C) 0 % to 45 %, 104 °F to 122 °F (40 °C to 50 °C) |
Battery Type and Life | 2 x AA (IEC LR6) 360 hrs continuous Typical; 200 hrs using Field Sense |
Temperature Coefficient | 0.1 x (specified accuracy) for 64.4 °F to 82.4 °F (18 °C to 28 °C) |
Dimensions | 2.4 in x 10.2 in x 1.7 in (61.1 mm x 259.3 mm x 43.8 mm) |