Description
Overview
GAOTek energy meter tester has a versatile meter system that supports simultaneous verification of active and reactive inductive energy meters, as well as electronic energy meters in a four-wire system. It automatically calculates rounding errors, checks load management and transformer monitoring errors, enhancing reactive power accuracy to 0.1%. Features include digital true reactive power measurement, comprehensive pre-power and maintenance checks, event record readings, it can identify and correct various wiring errors, measure waveform and harmonics, and communicate with field terminals and PCs. The meter system also supports barcode scanning, upgrades via U disk or serial port software, and seamless integration with marketing systems.
Features
- Three phase energy meter on-site tester
- Error verification of electric energy meter
- Meter clock error check
- Electric energy meter wiring inspection and recovery rate calculation
- TA magnification check
- Check hte meter and meter
- Electric energy meter communication detection
- Waveform test, 2-51 harmonic
- Self-calibration of clamp error
- Supports USB and COM Port
- Â Compatible with TV or lithium battery power supply
- Accuracy 0.05 and 0.1
Technical Specification
Features | Support USB, COM, Bluetooth, Wi-Fi interface |
Harmonic Measurement Range | 2 to 63 harmonics |
Data Storage | 10000 |
Communication Protocol | 645 or 698 |
Measurement Technology | digital true reactive power measurement |
Input Function | support barcode scanning |
Calibration Function | error self-calibration |
Battery Powered | Compatible with TV or Lithium battery |
Power Consumption | about 5 VA |
Display Function | identify wiring errors, prompt correction factor |
Voltage Range | AC 0 to 480 V |
Current Range | Double the overload, correct measurement |
Terminal Input | 1 A,5 A |
Clamp Meter Input | 5 A,20 A,100 A,500 A, 1000 A, 1500 A |
Frequency | 45 Hz to 65Hz |
5a | FL= 36000 PkWh FH= 3.6 x 108 P |
Clamp Meter Input | grade |
Transformer Ratio | <±0.5% |
Voltage Influence | <±0.01% |
Frequency Effect | <±0.01%(45 Hz to 65 Hz) |
Measuring Range | 2 to 63 times |
Measurement Accuracy | ±0.01 % (relative to 100% fundamental wave) |
Terminal Input | Level 0.1 Level 0.05 |
Active Energy | ±0.1 % ±0.05 % |
Reactive Energy | ±0.1 % ±0.1 % |
Power | ±0.1 % ±0.05 % |
Voltage | ±0.1 % ±0.05 % |
Current | ±0.1 % ±0.05 % |
Frequency | ±0.05 Hz ±0.05 Hz |
Phase | ±0.1° ±0.05° |
Power Supply | AC 50 V to 450 V(45 Hz to 65 Hz) |
Battery Powered | 6 hrs of continuous work |
Power Consumption | About 5 VA |
Ambient Temperature | -4° F to 122° F (-20° C to +50° C) |
Relative Humidity | 40% to 95% no condensation |
Size | 9.8 in × 6 in × 2.2 in (249 mm × 154 mm × 58 mm) |
Dimensions | 14.1 in × 10.3 in × 5.9 in (360 mm × 264 mm × 150 mm) |
Weight | 3.9 Ib (1.8 Kg) of host or 1.5 Ib (700 g) signal source |