Description
Features
- Measurement display mode
- Positive wave, negative wave, full wave and wave
- It has a linear suppression function
- The maximum inhibition is 80% of the screen height
- It can switch between single crystal probes
- Double crystal probe and two inspection modes
- It has a gate setting and alarm function
- The position and width
- The gate can be arbitrarily set on the screen
- An incoming wave alarm can be set
- 500 independent detection channels
- Each channel set a separate set of testing parameters
- DAC curve
- Two display modes with angle and K value
- The DAC curve is generated automatically
- up to 10 points can be recorded
- With four additional adjustable offset curves
- AVG curve is generated automatically
- Two types of defects can be customized
- Automatic probe calibration function
- With storage function
- it can store 100 A sweep patterns
- Parameters and D AC curve
- Has a storage graphics playback function
- The stored A scan graphics from the storage area
- Displayed on the screen
- Has a delete function to delete
- The specified content from the storage area
- Peak memory function
- Freeze and thaw functions with waveform
- Inspection parameters
- With sound path measurement
- Echo frequency analysis function
- Realtime power status indication function
- Support USB communication interface
- Li battery, low power consumption
- Can continuous working more than ten hours
- Can set up buzzer alarm during operation
- Light, convenient, easy to operate
Â
Technical Specifications
Scan range | Scan range (mm): 0 in to 393.7 in (0 mm to 10000 mm)Grades: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350, 400, 450,500,600,700,800,900,1000,2000,3000,4000,5000,6000,7000,8000,9000, 10000. Adjusting step distance: 0.03 in (1 mm) |
Pulse shift | Pulse shift (ms): -7 ms to +9984 msGrades: -20, -10, 0.0, 10, 20, 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600,
700,800,900,1000,1500,2000,2500,3000,3400. Adjustment step:1(-7 ms to 9984 ms) |
Probe zero point | Probe zero point:0.0 ms to 99.99 msAdjust the step:0.01 |
Material sound speed | Material sound speed: 3280.84 ft/s to 49212.6 ft/s (1000 m/s to 15000 m/s)7 fixed sound speeds:2260,2730,3080,3230,4700,5900,6300
Adjust the step:1 |
Working methods | Single probe (receive and send), dual probes (one for receiving one for sending) |
Frequency Range | 0.5 MHz to 20 MHz |
Gain adjustment | 0 dB to 120 dBAdjust the step:0.2,1,2,4,6,8,10,20,50 |
Linear inhibition | Screen height 0% to 80%, step size: 1% |
Vertical linearity error | Vertical linear error, not more than 3% |
Horizontal linear error | Within the scan range, not more than 0.2% |
Flaw detection sensitivity margin | ³62 dB |
Dynamic Range | ³32 dB |
Alarm | Incoming wave alarm |
Display screen | Display:High brightness color 5.7 in (14.47 cm) display |
A Scan display area | Full screen or localA Scan shows freeze and thaw A Scan-fills |
Flaw detection channel | 300 |
Data storage | 500 A Scan graphics |
PC communication interface standard | USB |
Units of measurement | Mm |
Power Adapter | enter 100 V to 240 V or 50 Hz to 60 HzOutput 9 V or 1.5 A |
Battery | Lithium (Li) Battery 5000 mAh |
Working temperature | 32 °F to 122 °F (-10 °C to 50 °C) |
Working humidity | 20% to 90% RH |
Interface Type | BNC |
Dimensions | 8.66 in x 5.5 in x 1.9 in (220 mm x 140 mm x 50 mm) |
Weight | 2.20 lb (1.0 kg) |