Description
Technical Specifications
Product Type | Online, Hydrogen Cyanide |
Sensor | Electrochemical Gas sensor |
Detection Pattern | Diffusion, pipeline (screw thread size ( M 40 mm x 1.5 mm), Circulation, Pumping is available, Online detection |
Detection Range | 0 ppm to 30 ppm,50 ppm,100 ppm,500 ppm,1000 ppm |
Resolution | 0.01 ppm (0 ppm to 100 ppm), 0.1 ppm (0 ppm – 1000 ppm) |
Detection Accuracy | ≤ ± 3 % F.S |
Reaction Time | ≤ 20 S (T90) |
Recovery Time | ≤ 20 S |
Relay output | Two relays output, Contact rating:24VDC 3A /220 V AC 3 A |
Explosion Proof Sign | ExdII CT6, Certification Number of Explosion-proof: CNEx10.1807 |
Outputs | Analog: 4 mA to 20 mA signal, 0 V to- 5 V, 0 V to 10 V Modbus: RS485 signal Pulse signal or TCP/IP signal, optional |
Alarm Setting | Two alarm set points Alarm mode optional: Low Alarm-High alarm / High Alarm-High alarm / Low Alarm-Low alarm |
Controllers | Compatible with DN3000 / DN9000, as well as most DCS/PLC systems |
IP Rating | IP65 |
Material | Aluminum, Explosion and corrosion proof |
Linearity error | ≤ ± 1 % FS |
Zero drift | ≤ ± 1 % (FS/Year) |
Repeatability | ≤ ± 1 % FS |
Standard Accessories | -User manual -Certification -Calibration cover |
Optional Accessories | -Hose (5 mm x 8 mm), drying tube, water separator or pumping pump -Infrared remote control -Temperature and humidity sensor, SMS alarm,3G module or wireless transmission module |
Connection | 3/4″NPT, 1/2″NPT |
Operating Pressure |
0 psi to 29 psi (0 Kpa to 200 Kpa) |
Relative Humidity | ≤ 90 % RH, Non-condensing |
Operating Temperature |
-22 °F to 140 °F ( -30 °C to 60 °C) |
Dimensions | 7.87 in x 6.69 in x 3.14 in (200 mm × 170 mm × 80 mm) |
Weight | 3.31 lb. (1.5 kg) |