Technical Specifications
Gas Detected | Toluene C7H8 |
Detection principle | Photoionization principles or Principles of Semiconductors or Infrared principles |
Sampling Method | Pump- suction, flow up 1 L/min, pump suction size ten stalls adjustable |
Data logger | 100,000 sets of data can be stored, storage interval available set, minimum 5 S, can be browse |
Measure Range | 0 to1 ppm,10 ppm,50 ppm,100 ppm,200 ppm,1000 ppm,2000 ppm,5000 ppm, 0 %to 2 % Vol,100 % LEL |
Resolution | 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 % Vol, 0.01 % LEL |
Precision | 2 % FS |
Measure Range2 | 0 % to 2 % Vol, 100 % Lel |
Response Time | ≤ 10 S |
Repeatability | ≤ ± 1 % |
Zero shift | ≤ ± 1 % (F.S / Year) |
Alarm mode | Sound, light, vibration |
Explosion-Proof | Exia II CT4 |
Alarm mode | Sound, light, vibration |
Recovery Time | ≤ 10 S |
Linearity error | ≤ ± 1 % |
Display | LCD |
Gas unit | Multiple gas unit |
Humidity | 0 % to 95 % RH |
Degree of protection | IP 66 |
Operating time | 100 hours (off pump) |
Temperature | -40 °F to 158 °F (-40 °C to 70 °C) |
Dimensions | 8.07 in x 2.95 in x 1.25 in (205 mm x 75 mm x 32 mm) |
Weight | 10.58 oz (300 g) |