Description
Overview
GAOTek Gas Test Instrument is a specialized device designed for detecting and analyzing nitrogen gas (N2) leaks. It offers a fast response time of 10 seconds and is capable of measuring nitrogen gas concentrations in the range of 0 to 100 % volume. The instrument is primarily used for leak detection purposes, ensuring the integrity and safety of nitrogen gas systems. It is an essential tool for industries such as manufacturing, aerospace, electronics, and HVAC that rely on nitrogen gas for various applications.
Features
- It can detect 1 to 5 kinds of gases at the same time, and the unit can be switched
- The sampling distance is larger than 32.81 ft (10 m), and the special gas circuit design can be directly detected
- Using 5500 mA large-capacity rechargeable polymer battery
Multiple alarm mode settings - Low alarm, high alarm, interval alarm, weighted average alarm
- Mistaken operation recognition function
- Zero-point automatic tracking, long-term use will not be affected by zero-point drift
- Multi-level calibration of target points to ensure linearity and accuracy of measurement Chinese and English interface can be selected
Technical Specifications
Detection gas | Nitrogen N2 |
Scope of detection | 0 to 100 % Vol |
Resolution | 0.01 % Vol (0 to 100 % Vol) |
Detection principle | Electrochemical principles |
Sensor life | 5 years |
Detection method | Built-in pump suction, flow rate 500 ml/min |
Display method | 2.5 in (6.35 cm) 320 x 240 high-definition colour screen display, 5-buttons operation |
Power supply | DC3.6V |
battery capacity | 3.6 VDC, 5500 mA large-capacity rechargeable polymer battery, with overcharge, over-discharge, overvoltage, overheating, and short circuit protection functions |
Use environment | Temperature -40 °F to 158 °F (-40 ℃ to 70 ℃); Relative humidity ≤ 0 to 99 % RH (built-in filter can be used in high humidity or high dust environment) |
Sample temperature | -40 °F to 158 °F (-40 ℃ to 70 ℃), optional with extra charge high temperature sampling probe, can detect the flue gas concentration of 800 degrees or higher |
Data storage | Standard configuration of 100,000 data capacity, support history viewing, deletion or data export, free host computer communication software. The storage function is off by default, and can be set to on, and the storage time interval can be set arbitrarily. |
Communication Interface | USB (charging and communication), RS232, infrared communication, automatic identification |
Printer | Optional extra charge external mini wireless infrared thermal printer |
Interface language | Chinese or English can be set |
Linearity | ≤ ± 2 % |
Response time |  ≤ 20 s |