Description
Feature
- Easily and friendly for installation and operation.
- Adopts a new external clamp design, which could get the flow rate without touch the measurement medium
- As the advantage of a clamp on flow meter, no need to cut off the pipe or long time stop the equipment, save the cost of time and labour costs
- A variety of modes are available for setting and flexibility. One set is universal for all pipe size in the measuring range, and suitable for many kinds of metal and resin pipes
- 56 x 128 LCD display. Display a variety of information.
- It is optional to become an ultrasonic cooling (heat) meter/ btu meter/ energy meter to realize the monitoring and measurement of energy
Technical Specification
Pipe material |
Metal /PVC, PP or PVDF rigid plastic pipe |
Liquid type |
Water/other liquid (Single liquid medium without solid particles or impurities) |
Temperature range |
32 ℉ to 167 ℉ (0 ℃ to 75 ℃) (No freezing on the surface) |
(Default by factory) |
0.1m/s |
Display |
256-pixel x 128-pixel, LCD |
Response time |
0.5 s to 60 s |
Accuracy |
±2%, (±1% after calibration) |
Data Storage period |
300 m |
Memory for data backup |
EEPROM (Data storage: over 10 years, data read/write frequency: over 1 million times) |
Power and I/O connection |
M12 type aviation plug |
Output |
4 mA to 20 mA |
Communication |
Modbus RS485 |
(Options for output) |
OCT (pulse output)/ One relay alarm (please contact the factory) |
Power supply |
10 V to 24 V (DC) |
Electric power |
3 W |
Protective circuit |
Power reverse connection protection, Power surge protection, Output short circuit protection, Output surge protection |
Enclosure protection class |
IP 65 |
Environment temperature |
50 ℉ to 140 ℉ (10 ℃ to 60 °C) (No freezing) |
Relative humidity |
35% RH to 85% RH (No condensation) |
Vibration resistance |
10 Hz to 55 Hz |
Impact resistant |
double amplitude 0.0591 in (1.5 mm), 2 hrs in each XYZ axis 100 ms2 16 Ms pulse, 1000 times each for X, Y and Z axis |
Main material |
Aluminium, Industrial Plastics |
cable length |
2 m (standard), PT1000 sensor standard cable length is 354.331 in (9 m) |