Description
Overview
GAOTek impedance analyzer LCR meter meters are versatile, extremely accurate and perform measurements quickly. They are ideal for challenging applications in research, development, and production. Two instrument models and various options cover applications with a test signal frequency of up to 10 MHz. Internal and external bias functions, comprehensive analysis options and versatile test fixtures expand the wide range of possible applications. These products have an upper frequency limit of 500 kHz and can be extended to 1 MHz or 10 MHz using software options when needed. All instruments offer DC measurements as well. Internally generated voltages of up to 10 V cover most applications. Optionally, bias voltages of up to 40 V can be applied externally. A fast-logging function records all measured values up to 10 times per second. Dynamic impedance measurements can be performed using the advanced analysis function. In these sweep measurements, the impedance values are determined for a series of frequency values or other parameters.
Features
- Universal LCR meter
- Fast, accurate and versatile
- Selectable frequency range
- Test signals for all requirements
- DC bias
- Measurement functions
- Data logging function
- Easy operation
- High-resolution touchscreen
- Graphical representation of measurements
- Save and recall instrument settings
- Tailored for use in labs and system racks
- Full remote capabilities
Technical Specification
Frequency Range | 4 Hz to 10 MHz |
Basic Accuracy | ± 0.05% |
Phase Measurement | ± 0.03° |
DC Bias | 40 V |
DC Bias Current (Internal) | 0 mA to 200 mA |
Internal Bias Voltage | 0 V to 10 V |
External DC Bias Voltage, Input | 0 V to +40 V |
Source Impedance | 100 Ω to 10 Ω |
Measurement Range | 10 MΩ to 100 MΩ |
Temperature (Base Units and Test Fixtures | operating temperature range +41 °F to +104 °F (+5 °C to +40 °C) storage temperature range -4 °F to 158 °F (-20 °C to +70 °C) |
Humidity | Without condensation, 5% to 95% |
Altitude | Operating altitude max. 1.24 mi (2000 m) above sea level |
Mains Nominal Voltage | 100 V to 240 V AC (±10%) |
Mains Frequency | 50 Hz to 60 Hz |
Maximum Power Consumption | 60 W (meas.) |
Rated Current | Max. 1 A (meas.) |
Mains Fuses | IEC 60127-2/5 T2.0H/250 V |
Electromagnetic Compatibility | EU: in line with EU EMC Directive 2014/30/EU, Applied standards:
|
Electrical Safety | EU: in line with Low Voltage Directive 2014/35/EU, Applied harmonized standard: EN61010-1 USA, Canadá: CAN/CSA C22.2 No. 61010-1-12 |
Rohs | In line with EU Directive 2011/65/EU, EN IEC 63000 |
Vibration | Sinusoidal 5 Hz to 55 Hz, 0.3 mm (peak-to-peak), 55 Hz to 150 Hz, 0.001 lb (0.5 g) constant, In line with EN 60068-2-6 Wideband noise 8 Hz to 500 Hz, acceleration: 0.002 lb (1.2 g (RMS)), In line with EN 60068-2-64 |
Shock | 0.088 lb (40 g) shock spectrum, In line with MIL-STD-810E, method 516.4, procedure |
Recommended Calibration Interval | Operation 40 h/week over entire range of specified environmental conditions; 1 year |
Dimensions | 14.25 in x 3.9 in x 14.06 in (362 mm x 99 mm x 357 mm) |
Weight | 5.95 lb (2.7kg) |