Description
Features
- 200 MHz or 100 MHz or 60 MHz bandwidth
- 1 GSa/s Real Time sample rate
- Large (7.0 in (17.7 cm)) color display, WVGA (800 x 480)
- Record length up to 2 M
- Trigger mode edge or pulse width or line selectable video or slop
- USB host and device connectivity, standard
- Multiple automatic measurements
- Four math functions, including FFTs standard
Technical Specifications
Bandwidth | 200 MHz |
Real-time Sample Rate | 1 GSa or s |
Equivalent Sample Rate | 25 GSa or s |
Inputs Coupling | AC, DC, GND |
Inputs Impedance | 1 MΩ ± 2 %, 20 pF ± 3 pF |
Probe Attenuation | 1 X, 10 X |
Supported Probe Attenuation Factor | 1 X, 10 X, 100 X, 1000 X |
Sample Rate Range | 500 MS or s to 1 GS or s |
Waveform Interpolation | (sin x) or x |
Sample Rate and Delay Time Accuracy |
± 50 ppm (at over any ≥ 1 ms time interval) |
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot, Normal mode ± (1 sample interval +100 ppm × reading + 0.6 ns), >16 averages ± (1 sample interval + 100 ppm × reading + 0.4 ns), Sample interval = s or div ÷ 200 |
Offset Range | 2 mV or div to 20 mV or div, ± 400 mV, 50 mV or div to 200 mV or div, ± 2 V 500 mV or div to 2 V or div, ± 40 V, 5 V or div to 10 V or div, ± 50 V |
SEC or DIV Range | 4 nS or div to 40 S or div |
Rise Time at BNC (typical) | 1.8 ns |
Vertical resolution | 8 bit resolution, each channel sampled simultaneously |
Position Range | 2 ns or div to 8 ns or div, (-8 div x s or div) to 20 ms |
Math | +, -, *, /, FFT |
FFT | Windows Hanning, Flat top, Rectangular, Bartlett, Blackman, 1024 sample point |
Bandwidth Limit | 20 MHz |
Low Frequency Response (-3db) | ≤ 10 Hz at BNC |
DC Gain Accuracy | ± 3 % for Normal or Average acquisition mode, 10 V or div to 10 mV or div, ± 4 % for Normal or Average acquisition mode, 5 mV or div to 2 mV or div |
Volts measurement repeatability, Average Acquisition Mode |
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative |
Trigger Source | CH1, CH2, EXT, EXT/5, AC Line |
Trigger Modes | Auto, Normal, Single |
Coupling Type | DC, AC, Noise Reject, HF Reject, LF Reject |
Trigger Level Range | CH1 or CH2 ± 8 divisions from centre of screen, EXT ± 1.2 V, EXT/5 ± 6 V |
Set Level to 50 %(typical) | Operates with input signals ≥50 Hz |
Video Trigger Type | CH1, CH2 Peak-to-peak amplitude of 2 divisions, EXT 400 mV, EXT/5 2 V |
Signal Formats and Field Rates, Video Trigger Type | Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
Hold off Range | 100 ns to 10 s |
Pulse Width Trigger Mode | Trigger when (<, >, =, or ≠), Positive pulse or Negative pulse |
Pulse Width Range | 20 ns to 10 s |
Slope Trigger Mode | Trigger when (<, >, =, or ≠); Positive slope or Negative slope |
Time Range | 20 ns to 10 s |