Description
Features
- Handheld, industry use, high sensitivity and accuracy
- Intrinsically safe, Ex sign is ExibdI
- Rugged ABS+PC case, heavy duty, crash resistant
- High-capacity chip, 4 layers PCB board
- Visual & audible alarm
- High & low alarm point, fully adjustable
- SETL & TWA alarm
- Low battery alarm
- Rechargeable battery
- LCD large screen display with Real time of target gas concentration
- clock and status of battery
- With Stainless Steel belt clip
- Support data logging function
- External air sampling pump is available for gas leak detection.
Technical Specifications
Gas detected | Nitrogen Monoxide (NO) |
Measuring range | (0 ppm to 100 ppm), (0 ppm to 250 ppm) |
Resolution ratio | 0.1 ppm |
Sensor | CITY Electrochemical Sensor |
Sensor lifetime | ≥ 2 year |
Response time | ≤ 45 s (T90) |
Alarms | Audible-buzzer with ≥ 75 dB audible Visible-flashing red LED, ≥ 20 m visible |
Alarm point | Fully adjustable |
Data logging (optional) | Continuous Data logging (9000 data at configurable 0.1 minutes to 10 minutes intervals) |
Continuous working time | > 3 months (without backlight) |
Working current | < 1 mA (without backlight) |
Display | Liquid crystal display (LCD) |
Battery model | PL123450, 3.7 V or 1500 mA |
Charging time | 4 hours to 5 hours |
Dust and water resistance | IP54 |
Size & | 4.13 in x 2.12 in x 1.25 in (10.5 cm x 5.4 cm x 3.2 cm) |
Ex sign | ExibdI |
Working temperature | – 13 °F to 131 °F (- 25 °C to + 55 °C),
short time: – 40 °F to 131 °F (- 40 °C to + 55 °C) |
Weight | 15.87 oz (450 g) |