GAOTek Noise Dose Meter

GAOTek Noise Dose Meter is a parameter used to quantify noise exposure measured in a period, during turns of % noise exposure relative to 90dBA for 8 hours.

SKU: GAOTek-RTS-105 Category:
Description

Description

Overview

GAOTek Noise Dose Meter is a parameter used to quantify noise exposure measured in a period, during turns of % noise exposure relative to 90dBA for 8 hours., 100% DOSE = 90dBA for 8 hours This is known as the Criterion. Other criterion is available such as 100% DOSE = 85 dBA for 8 hours to meet legislation in different countries. If the person stayed in this environment for 4 hours, he would receive 50%DOSE. Also if the noise level was said 93 dBA, 3 dB higher, a 100% DOSE would be accumulated in only 4 hours, The above example is for a dose meter with 3dB Exchange Rate, where a 3dB increase in sound level corresponds to a doubling energy. A dose meter with 5dB Exchange Rate is also, available where the sound must increase by 5dB to double the dose as required to meet noise legislation in some countries.

 

Features

  • User-Friendly Operation
  • 8 Built-in Standard Dose Setups
  • 9 User-Defined Setups
  • Single Sound Level Meter Setup
  • 50 Dose Result Stores
  • Keypad Lock for Protection
  • Timers for Measurement Control
  • USB Data Output for PC Connection

 

Technical Specification

Parameter Value
Microphone 1/2-inch Electret Condenser, 31-inch Cable
Display Liquid Crystal Display
Measurement Ranges 60 dB to 130 dB (A and C), 70 dB to 140 dB (A and C)
Peak Ranges 93 dB to 133 dB Peak, 103 dB to 143 dB Peak
Frequency Weightings RMS: A or C, Peak: C or Z (Linear)
Time Weightings Fast and Slow (RMS Detector)
Exchange Rate 3, 4, 5, or 6 dB
Stabilization Time 10 seconds from power on
Threshold and Criterion Levels User-defined setups: Threshold 70 dB to 90 dB, Criterion 80, 84, 85, or 90 dB
Under-Range Indications High Level Detector at 115 dB
Keypad Lock Lock/Unlock with Key Combinations
Clock Real-time Clock with Calendar
Memory Results from 50 measurements stored
Measurement Control Duration: 5, 10, 15, 30 mins, 1, 2, 4, 8, 10, 12, or 24 hours
Timers Up to 16 timers, Timer Controlled Start/Stop
Logging All measurement parameters logged
Logging Period (LP) 1s, 2s, 5s, 10s, 15s, 20s, 30s, 1min, 2min, 5min, 10min, 15min, 20min, 30min, or 60min
Logging Capacity 120,000 values can be stored at any one time
Setup 8 built-in default setups, 9 user-defined setups
Output USB Interface
Power Supply 4×1.5V AAA Size (UM-4) Battery
Battery Indicator Symbol indication of battery voltage level, flashes when voltage is insufficient
Operating Temperature & Humidity 32 ℉ to 122 ℉ (0 °C to 50 °C), 10 – 90 % RH
Storage Temperature & Humidity  14 ℉ to 140 ℉ (-10 °C To 60 °C), 10 – 75 % RH
Size 5.51 in × 2.83 in × 1.34 in (139.954 mm× 71.884 mm × 34.036 mm)
Weight Approx. 0.772 lb (0.3498 kg)