Description
Overview
The combination of the GAOTek Phased Array Flaw Detector live total focusing method (TFM) envelope processing, up to 1,024 × 1,024 grid resolution, and vibrant color display make its TFM images stand out with exceptional detail. Defects appear sharp and clear with high resolution. The Acoustic Influence Map (AIM) tool provides you with an instant visual model of the sensitivity based on your mode, settings, and simulated reflector. The tool enables you to visualize the effect of a wave set (in TFM mode), see where sensitivity stops, and adjust your scan plan accordingly.
Features
- Detect Early-Stage HTHA
- Facilitates Flaw Interpretation and Sizing
- Single time-of-flight diffraction (TOFD) menu for accelerated workflow
- Improved fast phased array calibration lessens frustration
- 800% high amplitude range reduces the need to rescan
- Compatible with Existing Files and Setups
- Existing probes and scanners
- MX2/SX data files to compare new data with old and monitor changes through time
- MX/MX2/SX setups to facilitate procedure compliance
Technical Specifications
Category | Specification |
Size (W × H × D) | 13.2 in. × 8.7 in. × 5.9 in. (335 mm × 221 mm × 151 mm) |
Weight | 12.6 lb (5.7 kg) (with 1 battery) |
Onboard Storage | 64 GB internal SSD storage,
extendable with external USB drive; 25 GB maximum file size |
Storage Devices | SDHC™ and SDXC™ cards or most standard USB storage devices |
GPS | Yes (some regional exceptions) |
Alarms | 3 |
Wireless Connection | Yes (USB dongle sold separately) |
Connectors | 1 PA connector, 2 UT channels (2 P/R connectors each) |
Number of Groups | 8 groups (16:128PR and 32:128PR); 16:64PR offers 2 groups (PA, UT, or TFM) or 2PA + 1 UT |
Certifications | ISO 18563-1:2015, EN12668-1:2010 |
Display | |
Type | TFT LCD with resistive touch screen |
Size | 269 mm (10.6 in.) |
Resolution | 1280 × 768 pixels |
Inputs and Outputs | |
Ports | 2 USB ports (one behind the battery), 1 USB 3.0, HDMI video output, SDHC memory card, Ethernet |
Encoder | 2-axis encoder line (quadrature or clock/direction), 3rd encoder ready |
Digital Input | 6 digital inputs, TTL (for acquisition ON/OFF) |
Digital Output | 5 digital outputs, TTL |
Power Output Line | 5 V nominal, 1 A (short-circuit protected), and 12 V output at 1 A |
External DC Supply | 15 VDC to 18 VDC (min. 50 W) |
Connector | Circular, 2.5 mm pin diameter, center-positive |
Battery | |
Type | Lithium-ion battery |
Capacity | 93 Wh |
Number of Batteries | 2 |
Life | 5 hours (with 2 batteries; hot-swap capable) |
PA/UT Configuration | |
Effective Digitizing Frequency | Up to 100 MHz |
Max PRF | 20 kHz |
Display Refresh Rate | A-scan: 60 Hz; S-scan: 20 Hz to 30 Hz |
Envelope (Echo Dynamic Mode) | Yes: Volume-corrected S-scan (30 Hz) |
A-Scan Height | Up to 800% |
Data Specifications | |
Max A-Scan Data Points | Up to 16,384 |
Real-Time Averaging | PA: 2, 4, 8, 16; UT: 2, 4, 8, 16, 32, 64 |
Rectification | RF, full wave, half wave+, half wave |
Filtering | PA channel: 3 low-pass, 6 band-pass, and 4 high-pass filters |
Video Filtering | Smoothing (adjusted to probe frequency range) |
Programmable TCG | |
Number of Points | 32 (one TCG curve per focal law) |
Range | PA (standard): 40 dB per step of 0.1 dB; PA (extended): 65 dB per step of 0.1 dB; UT: 100 dB |
Maximum Slope | PA (standard): 40 dB/10 ns; PA (extended): 0.1 dB/10 ns; UT: 40 dB/10 ns |