Description
Features
- 200, 100, 70 MHz bandwidths
- 1 GSa/s Real Time sample rate
- Large (7.0-inch) color display, WVGA (800×480)
- Record length up to 40 K
- Trigger mode: edge, pulse width, line selectable video, slop, overtime etc
- USB host and device connectivity, standard
- Multiple automatic measurements
- Four math functions, including FFTs standard
- Provides software for PC real-time analysis
Technical Specifications
Sampling rate | Real-Time Sample: 1 GS/s Equivalent Sample: 25 GS/s |
Average | Waveform Average, selectable 4,8,16,32,64,128 |
Inputs coupling | AC, DC, GND |
Inputs impedance | 1 M ± 2% II 20 pF ± 3 pF |
Probe attenuation | 1X, 10X |
Supported probe attenuation factor | 1X, 10X, 100X, 1000X |
Maximum input voltage | 300 VRMS (10x), Installation Category;150 VRMS (1x); Installation Category II: derate at 20 dB/decade above 100 kHz to 13 V peak AC at 3 MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450 V. Excursion above 300 V should be of less than 100 ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300 V. If these values are exceeded, damage to the oscilloscope may occur. |
Horizontal sample range | 500 MS/s to 1 GS/s |
Horizontal waveform interpolation | (sin x)/x |
Horizontal record length | 40 K |
Horizontal SEC/DIV range | 2 ns/div to 80 s/div |
Horizontal sample rate and delay time accuracy | ±50 ppm (at over any ≥1 ms time interval) |
Horizontal offset range | 2 ns/div to 8 ns/div; (-8 div x s/div) to 20 ms; 20 ns/div to 80 us/div; (-8 div x s/div) to 40 ms; 200 us/div to 80 s/div; (-8 div x s/div) to 400 s |
Delta time measurement accuracy | Single-shot, Normal mode: ± (1 sample interval 100 ppm x reading 0.6 ns); >16 averages:± (1 sample interval 100 ppm x reading 0.4 ns); Sample interval = s/div / 200 |
Vertical resolution | 8-bit resolution, all channel sampled simultaneously |
Position range | 2 mV/div to 20 mV/div, ±400 mV; 50 mV/div to 200 mV/div, ±2 V 500 mV/div to 2 V/div, ±40 V; 5V/div to 10 V/div, ±50 V |
Bandwidth | 200 MHz, 100 MHz, 70 MHz |
Rise Time at BNC ( typical) | 1.8 ns, 3.5 ns, 5 ns |
FFT | Windows: Hanning, Flattop, Rectangular, Bartlett, Blackman; 1024 sample point |
Bandwidth limit | 20MHz |
Low frequency response (-3 db) | ≤10 Hz at BNC |
DC gain accuracy | ±3% for Normal or Average acquisition mode, 10 V/div to 10 mV/div; ±4% for Normal or Average acquisition mode, 5 mV/div to 2 mV/div |
DC measurement accuracy, average acquisition mode | When vertical displacement is zero, and N ≥16: ± (3% x reading 0.1div 1 mV) only 10 mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% x (reading vertical position) 1% of vertical position 0.2 div]; Add 2 mV for settings from 2 mV/div to 200 mV/div; add 50 mV for settings from 200 mV/div to 10 V/div |
Volts measurement repeatability, average acquisition mode | Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
Dimensions | 15.2 in x 7.9 in x 9.6 in (385 mm x 200 mm x 245 mm) LxWxH |
Weight | 7.72 Ib (3.5 Kg) |