Description
Overview
GAOTek portable industrial digital ultrasonic flaw detector can detect, locate, evaluate and diagnose various defects (cracks, inclusions, pores, etc.) in the workpiece quickly, conveniently, without damage, and accurately. It can be used both in the laboratory and on the engineering site. This instrument can be widely used in manufacturing, iron and steel metallurgy, metal processing, chemical industry and other fields that require defect detection and quality control. It is also widely used in online safety inspection and Life assessment in the fields of aerospace, railway transportation, boilers and pressure vessels, etc. The instrument can be widely used in locating and sizing hidden cracks, voids, disbands, and similar discontinuities in welds, forgings, billets, axles, shafts, tanks and pressure vessels, turbines, and structural components.
Features
- The core hardware is designed with ARM+FPGA,
- The software uses a highly reliable multitasking operating system
- Improves the function, portability, durability and reliability of the instrument.
- This instrument uses a master-slave menu and is designed with shortcut keys and a digital rotary knob.
- The instrument is light and portable and can be held with one hand.
Technical Specifications
Measuring Range | 0 in to 590.55 in (0 mm to 15000 mm), at steel velocity |
Material Velocity | 1000 m/s to 20000 m/s |
Gain | 110 dB max in selectable resolution 0.1 dB, 1.0 dB, 2.0 db , 6.0 dB |
System Linearity | Horizontal: +/-0.2% FSW, Vertical: 0.25 % FSH, Amplifier Accuracy +/-1 dB |
Sensitivity Leavings | More 50 dB (Deep 200 mmΦ 2 flat-bottomed hole) |
Dynamic Range | More 40 dB |
Bandwidth (amplifier bandpass) | 0.2 MHz to 20 MHz |
Pulse Displacement | More 32 dB |
Resolving Power | More 40 dB |
Noise | Less than 10 % |
Display Delay | -20 µs to 3400 µs |
Probe Delay/Zero Offset | 0 µs to 99.99µs |
Test Modes | Pulse echo, dual element and thru-transmission |
Pulser | Tunable Wave Pulser |
Pulse Repetition Frequency Ranges | From 20 Hz to 2000 Hz |
Pulse Energy | 100 V, 200 V, 250 V, 300 V, 500 V selectable |
Gate Monitors | Two independent gates controllable over entire sweep range |
Rectification | Positive half wave, negative half wave, full wave, RF |
Reject (suppression) | 0 % to 80 % full screen height |
Units | Inch or millimeter |
Transducer Connections | BNC or LEMO |
Power Requirements | AC Mains 100-240 VAC, 50-60 Hz |
Operating Temperature | 14 °F to 122°F (-10 ºC to 50 ºC) |
Storage Temperature | -22 °F to 122°F (-30 ºC to 50 ºC) |
Equipment Weight | 4.23 lb. (1.92 kg) |
Equipment Size | 10.35 in x 6.69 in x 2.40 in (263 mm × 170 mm × 61 mm) |