Description
Features
- Backlit 3.5 in (88.9 mm) LCD display for multiparameter water quality meter
- Auto-calibration (1-5 points) with USA, NIST, DIN buffers
- Auto diagnosis displays pH slope and offset for accuracy
- Offset calibration (1 point) for standard adjustment
- Reliable ORP measurements in relative/absolute millivolt modes
- Calibrate (2-5 points) with 8 concentrations, easy readout
- Auto diagnosis displays calibration points and slopes
- Auto-calibration (1-5 points) with standard recognition
- Selectable settings for versatile measurements
- Calibrate (1-2 points) with salinity and pressure compensation
- Accurate temperature compensation, Auto-Read, calibration reminder
- Auto-Power Off, memory for 500 data sets, USB interface
- Flexible power options for smooth meter use
Technical specifications
pH | Range | -2 pH to 20 pH |
Resolution | 0.001 pH,0.01 pH, 0.1 pH, selectable | |
Accuracy | ±0.002 pH | |
Calibration Points | 1 point to 5 points | |
pH Buffer Options | USA, NIST, DIN, 2 custom buffers | |
ORP (optional) | Range | ±1999.9 mV |
Resolution | 0.1 mV, 1 mV, selectable | |
Accuracy | ±0.2 mV | |
Calibration Points | 1 point | |
Ion(optional) | Range | 0.001 to 19999 |
Resolution | 0.001,0.01,0.1,1 | |
Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) | |
Measurement Units | ppm, mg/L, mol/L, mmol/L | |
Calibration Points | 2 points to 5 points (0.001,0.01, 0.1,1,10, 100,1000, 10000) | |
Conductivity | Range | 7.87 mS/in to 78.74 mS/in (2 mS/mm to 20 mS/mm) |
Resolution | 0.001,0.01,0.1,1 | |
Accuracy | ±0.5% F.S. | |
Calibration Points | 1 point to 5 points | |
Calibration Solutions | 0.000254 mS/in to 2842.92 mS/in(10 pS/cm to 111.8 mS/cm) | |
T temperature Coefficient | Linear (0.0 %/°F to 18.0 %/°F), pure water | |
Reference Temperature | 68 °F to 77 °F (20 °C to 25 °C) | |
Cell Constant | K= 0.1, 1, 10 or custom | |
TDS | Range | 0 ppm to 10.00 ppm,100.0 ppm,1000 ppm, 10.00 ppt, 200.0ppt |
Resolution | 0.01,0.1,1 | |
Accuracy | ±1% F.S. | |
TDS Factor | 0.1 to 1.0 | |
Salinity | Range | 0.00 psu to 42.00 psu (0.00 ppt to 80.00 ppt) |
Resolution | 0.01 | |
Accuracy | ±1% F.S. | |
Resistivity | Range | 0.00 MQ to 20.00 MQ |
Resolution | 0.01 | |
Accuracy | ±1% F.S. | |
DO | Range | 0.00 mg/L to 20.00 mg/L, Saturation: 0.0 % to 200.0% |
Resolution | 0.01 mg/L, 0.1% | |
Accuracy | ±0.2 mg/L, ±2.0% | |
Calibration Points | 1 point or 2 points | |
BarometricPressure Correction | (8.70 PSI to 16.32 PSI) 60.0 kPa to 112.5 kPa / 450 mmHg to 850 mmHg | |
Salinity Correction | 0.0 g/L to 50.0 g/L, manual |