Description
Features
- 2 Channel Digital Oscilloscope
- Arbitrary or Function Waveform Generator, Synchronizing Signal
- External Trigger
- The Keys for oscilloscope and waveform generator are separated for convenient to operate it simultaneously
- Large and clear display 7 in (17.78 cm) 64 K color LCD display
- Resolution (800 pixels x 480 pixels), clearer and more realistic waveform
-  Oscilloscope: 1GSa/s Sample Rate, 200 or 100 or 70 MHz Bandwidth
- More than 20 kinds of auto measurement functions
- Powerful Trigger Function:Â Edge, Video, Pulse, Slope, Over time, Alternative
- Arbitrary/Function Waveform Generator:Â 25 MHz, 12 bits resolution, 200 MHz DDS
- Arbitrary wave or square wave or sine wave or triangle wave
- Trapezoidal wave or pulse wave or DCÂ is easy to simulate transducer
- Support SD card, VGA function (optional)
- Integrated USB Host, Support USB disk storage
- USB interface or SD card system update
Technical Specification
Sample Rate | Sampling Rate Range: 1 GSa/s | |
Equivalent Sample Rate: 25 GSa/s | ||
Normal | Normal data only | |
Peak Detect | High-frequency and randon glith capture | |
Average | Waveform Average, selectable 4,8,16,32,64,128 | |
Inputs Coupling | AC, DC, GND | |
Inpits Impendance | 1 MΩ ±2% 20 pF ±3pF | |
Probe Attenuation | 1 X, 10 X | |
Supported Probe Attenuation Factor | 1 X, 10 X, 100 X, 100 0X | |
Maximum Input Voltage | CAT I and CAT II: 300 VRMS (10×) | |
CAT III: 150 VRMS (1×). | ||
Installation Category II: derate at 20 dB/decade above 100 kHz to 13 V peak AC at 3 MHz and above. For non-sinusoidal waveforms, peak value must be less than 450 V. Excursion above 300 V should be of less than 100 ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300 V. If these values are exceeded, damage to the oscilloscope may occur. | ||
Sample Rate Range | 1 GS/s | |
Waveform Interpolation | (sin x)/x | |
Record Length | 40 K | |
SEC/DIV Range | 2 ns/div to 40s/div | |
Sample Rate and | ±50 ppm (at over any ≥1ms time interval) | |
Delay Time Accuracy | ||
Position Range | 20ns/div to 80us/div; (-8div x s/div) to 40 ms;
200us/div to 40s/div; (-8div x s/div) to 400s |
|
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot, Normal mode: ± (1 sample interval +100 ppm × reading + 0.6 ns); >16 averages: ± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 |
|
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously | |
Position Range | 2 mV/div to 10 V/div | |
Bandwidth | 200 MHz | |
Rise Time at BNC (typical) | 1.8 ns or 3.5 ns or 5 ns |