GAOTek Power Meter With Magnetic Shielding (High Reliability)

GAOTek Power Meter with Magnetic Shielding (High Reliability) is a device equipped with special shielding materials or techniques to protect it from external magnetic interference.

SKU: GAOTek-PWM-102 Category:
Description

Description

Overview

GAOTek Power Meter with Magnetic Shielding (High Reliability) is a device equipped with special shielding materials or techniques to protect it from external magnetic interference. The primary purpose of adding magnetic shielding to a power meter is to ensure high reliability and accurate measurements in environments where magnetic fields may be present. Used to measure 3-phase AC voltage, current, leakage current, phase between current and voltage, frequency, power energy, phase sequence and active power.

 

Technical Specifications

Function Measure three phase AC voltage, leakage current, current, active power, reactive power, apparent power, power, phase between current and voltage, phase between phase voltage, frequency, power energy, phase sequence
Power  6V DC (LR6 x 4 alkaline dry batteries, continuously working for 12 hours)
Test Mode Clamp CT, integral mode
Clamp Size 3.14 in × 3.41 in (80 mm × 80 mm) can clamp electric cable of 3.14 in (80 mm) diameter, or 3.77 in × 0.15 in (96 mm × 4 mm) flat cable and steel earth wires
Current Range AC 0.0 A to 2000 A, Resolution: 0.1 A
Power Range
AC 0.0 KW to 1200 KW, Resolution: 0.1 KW
Voltage Range AC 0 to 600 V, Resolution: 0.01 V
Frequency Range 25 Hz to 100 Hz, Resolution: 0.1 Hz
Phase Range 0.0 to 360.0 °C, Resolution: 0.1 ° C
Power Factor Range 0.3 to 1.0 (Capacitive or inductive), Resolution: 0.001
Power Energy Range 0.0000 KWh to 72000 KWh, Resolution: 0.0001 KWh
Measured Wire Position Measured wire at approximately the geometric center of the clamp
Data Storage 200 sets, “FULL” symbol indicate the memory is full
RS232 Interface With RS232 interface, download data to computer for analysis and management
Communication Wire RS-232 communication wire, 70.86 in (1.8 m)
Frequency 50 Hz ,60 Hz automatic identification
Gear Shift Automatic shift
Sample Rate About 2 times/second
Line Voltage Below AC 600 V line measurement
Display Mode LCD: 128 dots × 64 dots; Display area: 1.69 in × 1.14 in (43 mm × 29 mm)
Meter Size 10.82 in × 5.70 in × 1.57 in (275 mm × 145 mm × 40 mm)
Backlight Controlled by “*” key
Data Hold “HOLD” symbol appears
Overflow “OL” symbol appears
Automatic Shutdown Automatically shutdown about 15 minutes after power on to reduce battery consumption
Voltage Detection Low battery symbol appears to remind the replacement of battery when the battery voltage drops below 5.2 V
Weight 2.20 lb (1 kg) (with batteries and accessories)
Working Current 50 mA with enabled backlight; 25 mA with disabled backlight
Working Temperature 14 °F to 104 °F (-10 °C to 40 °C) Humidity: 80 % RH
Storage Temperature 14 °F to 140 °F (-10 °C to 60 °C) Humidity: below 70 % RH
Insulation strength AC 3700 V / rms (between core and shell)
Safety Specifications IEC1010-1, IEC1010-2-032, 2 class of pollution, CAT III (600 V)